Test a magnetic source geometry after removing a probe baseline
A magnetic-field reading depends on source geometry and sensor response. For the long straight vacuum wire approximation, magnitude B=μ0I/(2πr), and the field circles the wire according to the right-hand rule for conventional current. At radii .05 and .10 m the physical fields differ by a factor of two, but a common additive sensor offset can hide that ratio.
Learning outcome: Change only offset and compare raw ratios with difference-based current. Freeze the third-radius prediction. Separately compare an ideal solenoid with n doubled at fixed I and a loop with R doubled at fixed NI: predict factors two and one half.
Starting recap
Use a right-handed coordinate system, oriented surface normal, signed charge/current and declared energy boundary. Separate an entry force from a trajectory, emf from current, and rms from signed average.
All lessons are open directly. Your saved experiments remain when you leave and return.
Try
For I=3 A and offset1 µT, near reading is13 µT and far7 µT. The difference recovers12 µT physical near field, offset1 µT and current3 A. At .15 m the withheld indication is5 µT.
Open the experimentPredict
Two fitted wire-field readings establish:
Experiment
Change only offset and compare raw ratios with difference-based current. Freeze the third-radius prediction. Separately compare an ideal solenoid with n doubled at fixed I and a loop with R doubled at fixed NI: predict factors two and one half.
Infer a long-wire current separately from probe baseline
Worked teaching model · synthetic values · Vacuum long-straight-wire approximation, mu0=4pi×10⁻⁷ T m/A. Exact radial distances.05,.10,.15 m, same signed azimuthal component. A common additive sensor offset affects all readings. No nearby return wire, finite length or ferromagnetic material.
Reset keeps your prediction, captures and practice history.
Same-component long-wire field with sensor baseline
Unlike graph quantities rescale independently; read units and values, not screen angles. 1: one-over-radius plus offset (solid). Joined curves show the supplied model, not additional observations.
Equivalent numerical coordinates for Same-component long-wire field with sensor baseline
one-over-radius plus offset
| radial distance (m) | indicated azimuthal field (µT) |
|---|---|
| 0.05 | 13 |
| 0.05375 | 12.1628 |
| 0.0575 | 11.4348 |
| 0.06125 | 10.7959 |
| 0.065 | 10.2308 |
| 0.06875 | 9.72727 |
| 0.0725 | 9.27586 |
| 0.07625 | 8.86885 |
| 0.08 | 8.5 |
| 0.08375 | 8.16418 |
| 0.0875 | 7.85714 |
| 0.09125 | 7.57534 |
| 0.095 | 7.31579 |
| 0.09875 | 7.07595 |
| 0.1025 | 6.85366 |
| 0.10625 | 6.64706 |
| 0.11 | 6.45455 |
| 0.11375 | 6.27473 |
| 0.1175 | 6.10638 |
| 0.12125 | 5.94845 |
| 0.125 | 5.8 |
| 0.12875 | 5.66019 |
| 0.1325 | 5.5283 |
| 0.13625 | 5.40367 |
| 0.14 | 5.28571 |
| 0.14375 | 5.17391 |
| 0.1475 | 5.0678 |
| 0.15125 | 4.96694 |
| 0.155 | 4.87097 |
| 0.15875 | 4.77953 |
| 0.1625 | 4.69231 |
| 0.16625 | 4.60902 |
| 0.17 | 4.52941 |
| 0.17375 | 4.45324 |
| 0.1775 | 4.38028 |
| 0.18125 | 4.31034 |
| 0.185 | 4.24324 |
| 0.18875 | 4.17881 |
| 0.1925 | 4.11688 |
| 0.19625 | 4.05732 |
| 0.2 | 4 |
At most 82 representative computed coordinates including endpoints; the plotted curve can use a finer grid. A table of a revealed generator is not independent measurement evidence.
| Quantity | Value | Unit |
|---|---|---|
| Near field indication at .05 m | 13 | µT |
| Far field indication at .10 m | 7 | µT |
| Recovered near physical field | 12 | µT |
| Recovered field offset | 1 | µT |
| Inferred wire current | 3 | A |
| Withheld .15 m field indication | 5 | µT |
A common field offset disappears from differences but distorts a raw one-over-distance ratio.
For a long straight vacuum wire B=mu0 I/(2pi r), and direction follows a right-hand circulation around conventional current. Doubling r halves the physical field. Two readings identify current and offset only within this geometry; a withheld third radius tests that hypothesis. Finite wires, nearby return paths, ferromagnetic material and a tilted sensor can change the interpretation.
Predict before inspecting the values. Save contrasting records with assumptions and one alternative explanation. This virtual display does not certify practical measurement technique.
A common field offset disappears from differences but distorts a raw one-over-distance ratio.
For a long straight vacuum wire B=mu0 I/(2pi r), and direction follows a right-hand circulation around conventional current. Doubling r halves the physical field. Two readings identify current and offset only within this geometry; a withheld third radius tests that hypothesis. Finite wires, nearby return paths, ferromagnetic material and a tilted sensor can change the interpretation.
Captures preserve recipes and replay their calculated results. They are synthetic model evidence, not physical measurements.
Understand
Apply
Public practice checks a specific claim. It does not establish independent mastery.
Which independent observation could reject this model rather than merely refit its parameters?
Continue
Completion requires a saved prediction, at least one capture and a reflection. Presence checks do not grade your reasoning.
Skipping retains experiments and awards no mastery.
Save a science backup or import one
Science work is stored locally in this browser, separately from mathematics and AI. It does not sync automatically. Use this science-only backup; this checkout's older all-subject export does not include science.
A legacy file is available only when the complete snapshot fits the 36 MB limit. For larger snapshots, prepare a complete file set below; never discard notebooks to make a smaller file.
Matching imported notebook drafts replace their current drafts. Omitted lessons and known first attempts remain. Export your current work first if you want to retain both drafts.
Complete file sets and course backups
A file set can hold more work than one science file. Keep its manifest and every part together. Each file is limited to 36 MB. This format needs this version of LearnAI or a compatible newer version; older versions can use only the legacy single-file backup above.
The set includes every saved science course and global continuation at this moment. Later edits need a new export. A conflicting tab exports its own visible work, which may differ from saved work in another tab.
0 file(s) selected. File order and filenames do not determine identity. Missing, changed or conflicting parts block the entire restore; no good part is applied by itself.
Science storage: loading. No account or remote computation is required.