Learning preferences

Make learning more comfortable. Changes apply immediately.

Enlarges page content, including diagrams and their labels. You can also use your browser’s zoom.

Choose the colours that are easiest for you to distinguish. Applies to lesson diagrams and lab plots. Labels, shapes, hatching and line patterns also distinguish meanings. Source photographs and raw image brightness stay unchanged; mask-only views are available for image overlays.

ExampleComparisonSample link

Saved in this browser on this device. Preferences are separate from progress backups.

SCIENCE · INVESTIGATE AND EXPLAIN

Match renewable energy to the time of service

An energy total does not identify when energy is available. A system can generate enough electricity over a day yet fail to serve an evening need. Storage moves availability through time but introduces losses and finite power, capacity and operational constraints. Demand shifting is a different intervention that changes the timing of service.

Learning outcome: Compare requests 100, 200 and 300 at efficiency 0.8. Identify the point at which increasing the request cannot collect more surplus and reconcile every energy destination.

Starting recap

Fix the useful service, lifecycle boundary and scenario; distinguish a conditional model result from an observed causal improvement.

All lessons are open directly. Your saved experiments remain when you leave and return.

Try

Requested charge 200 and efficiency 0.8 give usable energy 160 kWh. Evening demand receives 150, usable remainder 10 and cycle loss 40. Together 150+10+40=200; no midday surplus is curtailed.

Open the experiment

Predict

A request to charge 300 kWh in this packet can actually charge:

Experiment

Compare requests 100, 200 and 300 at efficiency 0.8. Identify the point at which increasing the request cannot collect more surplus and reconcile every energy destination.

Match generation to service time with storage losses

Worked teaching model · synthetic values · Original midday generation 300 kWh, simultaneous demand 100; evening demand 150 kWh. Actual charge=min(request,200). Usable output=charge×efficiency; use up to evening demand and retain any remaining usable energy. Lump cycle losses into conversion; no power, capacity, degradation or charging-emissions constraint is included.

Reset keeps your prediction, captures and practice history.

Original synthetic system; units differ by row
QuantityValueUnit
Actual midday charge200kWh
Unstored midday curtailment0kWh
Cycle conversion loss40kWh
Evening demand served150kWh
Evening unmet demand0kWh
Usable energy retained10kWh

Daily generation totals cannot establish service at the time it is needed.

The cycle-equivalent ledger allocates charged energy to loss, evening service and usable remainder. Physical state of charge and finite power/capacity limits would require an explicit time-resolved storage model.

Predict, change one control, and save contrasting captures. Reconstruct the balance with units; then explain a process the ledger deliberately leaves out. Display precision is not measurement precision.

Daily generation totals cannot establish service at the time it is needed.

The cycle-equivalent ledger allocates charged energy to loss, evening service and usable remainder. Physical state of charge and finite power/capacity limits would require an explicit time-resolved storage model.

Captures preserve recipes and replay their calculated results. They are synthetic model evidence, not physical measurements.

Understand

Define the useful service

An energy total does not identify when energy is available. A system can generate enough electricity over a day yet fail to serve an evening need. Storage moves availability through time but introduces losses and finite power, capacity and operational constraints. Demand shifting is a different intervention that changes the timing of service.

Construct the comparable ledger

The original packet has midday generation 300 kWh and midday demand 100, leaving 200 available to charge. Actual charge cannot exceed that surplus even when a control requests more. Round-trip efficiency is usable output divided by input across a defined storage boundary; losses are not extra available energy.

Interpret the competing metrics

This simplified cycle-equivalent ledger multiplies actual charge by efficiency, serves up to 150 kWh evening demand, and retains any remaining usable energy. Unstored midday energy is curtailed. Charge equals cycle loss plus evening service plus retained usable energy. This is not a physical time-step state-of-charge simulation: it assigns full-cycle conversion losses at one accounting step.

Challenge the boundary and scenario

Power limits determine how fast charging and discharge can occur; energy capacity limits how much is stored. Degradation, standby losses, reserve needs and electricity emissions can alter a real comparison. Charging from a high-emission source is not automatically climate beneficial even if evening reliability improves.

Worked original packet

Requested charge 200 and efficiency 0.8 give usable energy 160 kWh. Evening demand receives 150, usable remainder 10 and cycle loss 40. Together 150+10+40=200; no midday surplus is curtailed.

Investigation

Compare requests 100, 200 and 300 at efficiency 0.8. Identify the point at which increasing the request cannot collect more surplus and reconcile every energy destination.

Changed-case transfer

At requested charge 150 and efficiency 0.8, find curtailment, evening service, unmet demand and loss.

Feedback

Actual charge 150, curtailment 50, usable/service 120, unmet evening demand 30 and loss 30 kWh. The 300 kWh generation total alone did not guarantee evening service.

Sources and evidence boundary

Original prose, numerical packets and exercises. Primary method/mechanism source, checked 30 October 2026. Supplied values are not measured operating data, universal coefficients or recommendations. No physical equipment work, chemical application, organism manipulation or water extraction is requested. Retain first reasoning and critique in the course workspace; public feedback is practice, not independent assessment.

Apply

A request to charge 300 kWh in this packet can actually charge:

Public practice checks a specific claim. It does not establish independent mastery.

At requested charge 150 and efficiency 0.8, find curtailment, evening service, unmet demand and loss.

Continue

Completion requires a saved prediction, at least one capture and a reflection. Presence checks do not grade your reasoning.

Skipping retains experiments and awards no mastery.

Save a science backup or import one

Science work is stored locally in this browser, separately from mathematics and AI. It does not sync automatically. Use this science-only backup; this checkout's older all-subject export does not include science.

A legacy file is available only when the complete snapshot fits the 36 MB limit. For larger snapshots, prepare a complete file set below; never discard notebooks to make a smaller file.

Matching imported notebook drafts replace their current drafts. Omitted lessons and known first attempts remain. Export your current work first if you want to retain both drafts.

Complete file sets and course backups

A file set can hold more work than one science file. Keep its manifest and every part together. Each file is limited to 36 MB. This format needs this version of LearnAI or a compatible newer version; older versions can use only the legacy single-file backup above.

The set includes every saved science course and global continuation at this moment. Later edits need a new export. A conflicting tab exports its own visible work, which may differ from saved work in another tab.

0 file(s) selected. File order and filenames do not determine identity. Missing, changed or conflicting parts block the entire restore; no good part is applied by itself.

Science storage: loading. No account or remote computation is required.