Learn

Learning preferences

Make learning more comfortable. Changes apply immediately.

Enlarges page content, including diagrams and their labels. You can also use your browser’s zoom.

Choose the colours that are easiest for you to distinguish. Applies to lesson diagrams and lab plots. Labels, shapes, hatching and line patterns also distinguish meanings. Source photographs and raw image brightness stay unchanged; mask-only views are available for image overlays.

ExampleComparisonSample link

Saved in this browser on this device. Preferences are separate from progress backups.

SCIENCE · INVESTIGATE AND EXPLAIN

Challenge competing concentration–time laws

Calibrate three laws on the same two anchors, discriminate with later bounded observations and transfer half-life predictions to a fresh concentration.

Learning outcome: Use concentration and transformed-time evidence to distinguish zero-, first- and second-order models without treating two-point agreement or a straight-looking plot as sufficient proof.

Starting recap

A concentration-time law predicts how much reactant remains. The disappearance-rate law is −dC/dt = kCⁿ; n is the candidate order, not a coefficient copied from a reaction equation.

All lessons are open directly. Your saved experiments remain when you leave and return.

Try

A sample falls from 0.100 to 0.050 mol/L in 10 s. Zero-, first- and second-order laws can all reproduce that first halving, but predict different later concentrations.

Open the experiment

Predict

Predict the three concentrations at 20 s and choose a later observation that could discriminate the laws. Would the same first half-life prove first order?

Experiment

Compare all three calibrated curves before revealing later packets. Use precise equal-fraction, reciprocal and equal-amount records, then inspect broad bounds, contradictory data and changed temperature. Compare original and transformed bounds. Capture one discriminating packet and one underdetermined or excluded comparison.

Distinguish time-course laws beyond two matching points

Worked teaching model · synthetic values · Original synthetic A → P at constant volume. C₀ = 0.100 mol/L and C(10 s) = 0.050 mol/L are exact calibration anchors at 300 K. Each candidate has disappearance rate −dC/dt = kCⁿ, with constant k. Later records are public checks, not calibration. Bounds are absolute limits, not confidence intervals; no actual experiment or unique mechanism is claimed.

Reset keeps your prediction, captures and practice history.

Fit two anchors; challenge the resulting law

Original synthetic fixed-volume A → P records use exact calibration anchors C₀ = 0.100 mol/L and C(10 s) = 0.050 mol/L at 300 K. For disappearance rate −dC/dt = kCⁿ, the selected order is 1 and k = 0.069314718 s⁻¹. Later public records do not refit k.

Time /sC ± bound /mol L⁻¹T /KRoleSelected prediction /mol L⁻¹Comparison
00.1 ± 0300Exact calibration anchor0.1Within supplied bound
100.05 ± 0300Exact calibration anchor0.05Within supplied bound

No eligible later check is available. All three orders fit the two anchors. A straight line through two transformed points does not discriminate them.

C /mol L⁻¹; circles and vertical bounds are eligible supplied records00.0250.050.0750.101020302: dotted1: solid0: dashed ends at 20 sTime /s; thicker curve = selected candidate

Inspect the transformation, including its domain

Selected vertical quantity: ln(C/C₀), dimensionless. Its candidate slope is -0.069314718 s⁻¹. Subtracting the initial transformed value makes every line start at zero. For order 1, ln uses the dimensionless ratio C/C₀. Logarithms and reciprocals require C > 0; zero concentration cannot be silently plotted there.

Time /sTransformed center /ln(C/C₀), dimensionlessTransformed boundUse
000 to 0Matched temperature
10-0.69314718-0.69314718 to -0.69314718Matched temperature
ln(C/C₀), dimensionless; fixed scale for this transformation-3-2-100102030Time /s; bounds transform exactly and need not stay symmetric

Do not compare apparent straightness or error-bar lengths across different vertical units as a statistical ranking. The compatibility decision above compares predictions with the original concentration bounds.

Transfer: halve the remaining sample, or start a fresh one?

At the same k and conditions, the first halving from 0.100 to 0.050 mol/L takes 10 s. The next halving from 0.050 to 0.025 takes a further 10 s. A fresh sample starting at 0.200 mol/L takes 10 s to reach 0.100. Only first order gives the same half-life in all three comparisons. These are conditional predictions, not fresh observations.

Sources and evidence limits

OpenStax Chemistry 2e §12.4 provides integrated-law and half-life relationships. The packets here are original public synthetic challenges. Exact initial concentration, calibration, fixed volume and constant temperature are assumptions. Matching a bounded family does not identify a unique mechanism or certify extrapolation.

No eligible later record: all three candidates match calibration alone.

The two calibration anchors determine each candidate constant; later public observations test rather than refit it. Distinguish conditional compatibility from proof of a universal law or mechanism.

Captures retain original time-course packets and your proposed order. Replay recomputes public-check compatibility and transformed bounds; it is not a new measured experiment or evidence of a unique mechanism.

Understand

Try: one halving does not identify the order

The original synthetic packet starts with two exact anchors: 0.100 mol/L at time zero and 0.050 mol/L at 10 s. All three candidate laws match. Before opening a later packet, predict which concentration at 20 s would distinguish them. The two anchors calibrate each law; the later public observations are checks and do not refit its constant.

Understand three different continuations

Write C for concentration in mol/L, C₀ for its initial value, t for elapsed seconds and k for a constant under the stated conditions. Here A → P has coefficient one, so disappearance rate and reaction rate coincide. The candidates assume −dC/dt = kCⁿ with order n equal to 0, 1 or 2.

  • Zero order removes the same amount per second: C = C₀ − kt. The anchors give k = 0.005 mol L⁻¹ s⁻¹. At 20 s this law reaches zero; its negative continuation is physically invalid.
  • First order removes the same fraction in equal times: C = C₀ exp(−kt). The anchors give k = ln(2)/10 ≈ 0.0693147 s⁻¹. At 20 s, C = 0.025 mol/L.
  • Second order has 1/C = 1/C₀ + kt. The anchors give k = 1 L mol⁻¹ s⁻¹. At 20 s, C = 1/30 ≈ 0.0333333 mol/L.

These k values have different units and cannot be ranked as comparable speeds merely by their numbers. The graph uses common concentration and time axes to compare the actual predictions.

Experiment: observations and their bounds

The equal-fraction packet selects first order from this family; the reciprocal and equal-amount packets discriminate differently. A broad concentration interval from 0.024 to 0.034 mol/L at 20 s still permits first and second order. Reporting one precise-looking best curve would conceal that ambiguity. The contradictory packet permits none, and the changed-temperature record cannot test the same k without additional temperature evidence.

All checks are original public synthetic records. Reopening them is practice, not a new independent observation. Candidate compatibility does not rule out other functional forms or identify a mechanism.

Connect the transformed graph

For zero order plot C−C₀, for first order plot ln(C/C₀), and for second order plot 1/C−1/C₀ against time. Each candidate predicts a line through zero. The natural logarithm ln reverses exponentiation; its argument C/C₀ is dimensionless. Reciprocals and logarithms are undefined at zero concentration. The table maps the actual interval endpoints, so transformed bounds can be asymmetric. Changing units or transformations changes graph scale; visual straightness alone is not a common error metric. Compare predictions with the original concentration bounds.

Apply: a fresh sample changes the test

All candidates take 10 s to halve the original 0.100 mol/L. But after that, zero order needs only 5 more seconds to halve the remainder, first order needs 10 and second order needs 20. A fresh 0.200 mol/L sample instead has first half-lives of 20, 10 and 5 s respectively at the same candidate k. Explain why the first half-life alone was insufficient evidence, then transfer repeated halving to the unfamiliar concentration and time in the practice question.

OpenStax Chemistry 2e §12.4 supplies the integrated-law relationships. Revisit the HS half-life explanation for a guided exponential refresher, or rate-window measurement for why estimated slopes require calibration and uncertainty. Actual empirical calibration, measurement dependence, volume changes, additional orders and independent practical review remain outside this bounded model.

Apply

An unfamiliar first-order sample decreases from 0.080 to 0.040 mol/L in 6 s under fixed conditions. How much remains after a further 12 s?

Public practice checks a specific claim. It does not establish independent mastery.

Explain why only first-order half-life is independent of starting concentration. Distinguish fitting the two anchors from testing later public records, and explain finite-depletion and positive-concentration domains.

Continue

Completion requires a saved prediction, at least one capture and a reflection. Presence checks do not grade your reasoning.

Skipping retains experiments and awards no mastery.

Save a science backup or import one

Science work is stored locally in this browser, separately from mathematics and AI. It does not sync automatically. Use this science-only backup; this checkout's older all-subject export does not include science.

A legacy file is available only when the complete snapshot fits the 36 MB limit. For larger snapshots, prepare a complete file set below; never discard notebooks to make a smaller file.

Matching imported notebook drafts replace their current drafts. Omitted lessons and known first attempts remain. Export your current work first if you want to retain both drafts.

Complete file sets and course backups

A file set can hold more work than one science file. Keep its manifest and every part together. Each file is limited to 36 MB. This format needs this version of LearnAI or a compatible newer version; older versions can use only the legacy single-file backup above.

The set includes every saved science course and global continuation at this moment. Later edits need a new export. A conflicting tab exports its own visible work, which may differ from saved work in another tab.

0 file(s) selected. File order and filenames do not determine identity. Missing, changed or conflicting parts block the entire restore; no good part is applied by itself.

Science storage: loading. No account or remote computation is required.