Challenge competing concentration–time laws
Calibrate three laws on the same two anchors, discriminate with later bounded observations and transfer half-life predictions to a fresh concentration.
Learning outcome: Use concentration and transformed-time evidence to distinguish zero-, first- and second-order models without treating two-point agreement or a straight-looking plot as sufficient proof.
Starting recap
A concentration-time law predicts how much reactant remains. The disappearance-rate law is −dC/dt = kCⁿ; n is the candidate order, not a coefficient copied from a reaction equation.
All lessons are open directly. Your saved experiments remain when you leave and return.
Try
A sample falls from 0.100 to 0.050 mol/L in 10 s. Zero-, first- and second-order laws can all reproduce that first halving, but predict different later concentrations.
Open the experimentPredict
Predict the three concentrations at 20 s and choose a later observation that could discriminate the laws. Would the same first half-life prove first order?
Experiment
Compare all three calibrated curves before revealing later packets. Use precise equal-fraction, reciprocal and equal-amount records, then inspect broad bounds, contradictory data and changed temperature. Compare original and transformed bounds. Capture one discriminating packet and one underdetermined or excluded comparison.
Distinguish time-course laws beyond two matching points
Worked teaching model · synthetic values · Original synthetic A → P at constant volume. C₀ = 0.100 mol/L and C(10 s) = 0.050 mol/L are exact calibration anchors at 300 K. Each candidate has disappearance rate −dC/dt = kCⁿ, with constant k. Later records are public checks, not calibration. Bounds are absolute limits, not confidence intervals; no actual experiment or unique mechanism is claimed.
Reset keeps your prediction, captures and practice history.
Fit two anchors; challenge the resulting law
Original synthetic fixed-volume A → P records use exact calibration anchors C₀ = 0.100 mol/L and C(10 s) = 0.050 mol/L at 300 K. For disappearance rate −dC/dt = kCⁿ, the selected order is 1 and k = 0.069314718 s⁻¹. Later public records do not refit k.
| Time /s | C ± bound /mol L⁻¹ | T /K | Role | Selected prediction /mol L⁻¹ | Comparison |
|---|---|---|---|---|---|
| 0 | 0.1 ± 0 | 300 | Exact calibration anchor | 0.1 | Within supplied bound |
| 10 | 0.05 ± 0 | 300 | Exact calibration anchor | 0.05 | Within supplied bound |
No eligible later check is available. All three orders fit the two anchors. A straight line through two transformed points does not discriminate them.
Inspect the transformation, including its domain
Selected vertical quantity: ln(C/C₀), dimensionless. Its candidate slope is -0.069314718 s⁻¹. Subtracting the initial transformed value makes every line start at zero. For order 1, ln uses the dimensionless ratio C/C₀. Logarithms and reciprocals require C > 0; zero concentration cannot be silently plotted there.
| Time /s | Transformed center /ln(C/C₀), dimensionless | Transformed bound | Use |
|---|---|---|---|
| 0 | 0 | 0 to 0 | Matched temperature |
| 10 | -0.69314718 | -0.69314718 to -0.69314718 | Matched temperature |
Do not compare apparent straightness or error-bar lengths across different vertical units as a statistical ranking. The compatibility decision above compares predictions with the original concentration bounds.
Transfer: halve the remaining sample, or start a fresh one?
At the same k and conditions, the first halving from 0.100 to 0.050 mol/L takes 10 s. The next halving from 0.050 to 0.025 takes a further 10 s. A fresh sample starting at 0.200 mol/L takes 10 s to reach 0.100. Only first order gives the same half-life in all three comparisons. These are conditional predictions, not fresh observations.
Sources and evidence limits
OpenStax Chemistry 2e §12.4 provides integrated-law and half-life relationships. The packets here are original public synthetic challenges. Exact initial concentration, calibration, fixed volume and constant temperature are assumptions. Matching a bounded family does not identify a unique mechanism or certify extrapolation.
No eligible later record: all three candidates match calibration alone.
The two calibration anchors determine each candidate constant; later public observations test rather than refit it. Distinguish conditional compatibility from proof of a universal law or mechanism.
Captures retain original time-course packets and your proposed order. Replay recomputes public-check compatibility and transformed bounds; it is not a new measured experiment or evidence of a unique mechanism.
Understand
Apply
Public practice checks a specific claim. It does not establish independent mastery.
Explain why only first-order half-life is independent of starting concentration. Distinguish fitting the two anchors from testing later public records, and explain finite-depletion and positive-concentration domains.
Continue
Completion requires a saved prediction, at least one capture and a reflection. Presence checks do not grade your reasoning.
Skipping retains experiments and awards no mastery.
Save a science backup or import one
Science work is stored locally in this browser, separately from mathematics and AI. It does not sync automatically. Use this science-only backup; this checkout's older all-subject export does not include science.
A legacy file is available only when the complete snapshot fits the 36 MB limit. For larger snapshots, prepare a complete file set below; never discard notebooks to make a smaller file.
Matching imported notebook drafts replace their current drafts. Omitted lessons and known first attempts remain. Export your current work first if you want to retain both drafts.
Complete file sets and course backups
A file set can hold more work than one science file. Keep its manifest and every part together. Each file is limited to 36 MB. This format needs this version of LearnAI or a compatible newer version; older versions can use only the legacy single-file backup above.
The set includes every saved science course and global continuation at this moment. Later edits need a new export. A conflicting tab exports its own visible work, which may differ from saved work in another tab.
0 file(s) selected. File order and filenames do not determine identity. Missing, changed or conflicting parts block the entire restore; no good part is applied by itself.
Science storage: loading. No account or remote computation is required.