Learn

Learning preferences

Make learning more comfortable. Changes apply immediately.

Enlarges page content, including diagrams and their labels. You can also use your browser’s zoom.

Choose the colours that are easiest for you to distinguish. Applies to lesson diagrams and lab plots. Labels, shapes, hatching and line patterns also distinguish meanings. Source photographs and raw image brightness stay unchanged; mask-only views are available for image overlays.

ExampleComparisonSample link

Saved in this browser on this device. Preferences are separate from progress backups.

SCIENCE · INVESTIGATE AND EXPLAIN

Infer isotope composition from a mass spectrum

Normalize a declared single-element signal and distinguish reference masses, sample composition and uncertainty.

Learning outcome: Calculate isotope fractions and a weighted mass, test scaling invariance and explain what an empty or bounded signal establishes.

Starting recap

Isotopes share proton count but differ in neutron count. A relative signal becomes a fraction only after dividing by its total under a stated response assumption.

All lessons are open directly. Your saved experiments remain when you leave and return.

Try

Two synthetic isotope signals are 75 and 25. Another record is 750 and 250. Does a larger signal imply a heavier average atom?

Open the experiment

Predict

Predict both normalized fractions and whether multiplying all signals by ten changes the weighted mean. Predict what should be reported when no signal is detected.

Experiment

Capture 75:25 and 750:250 with zero bound, then75:25 with bound 1. Inspect both pure-isotope endpoints and no-signal evidence. Use the table and fixed-scale spectrum to explain every comparison.

Infer composition from an isotope signal

Reference isotope masses · original synthetic detector signals · Original synthetic signals; NIST reference neutral isotope masses. One element, singly charged monatomic ions and equal isotope response. No mixed-element spectra or molecular fragments. Bound is absolute, not probabilistic.

Reset keeps your prediction, captures and practice history.

From relative signal to isotope fractions

Original synthetic record: 75 : 25 signal. Signals are arbitrary detector units, not measured atom counts. Equal isotope response is stipulated. Source masses below are reference neutral-atom masses; the spectrum uses nominal isotope positions for singly charged monatomic ions. Ion electron-mass corrections are omitted at this display resolution.

All supplied channels; zero is retained
IsotopeReference mass (u)SignalFraction
Chlorine-3534.96885268275 ± 00.75
Chlorine-3736.96590260225 ± 00.25

Total signal = 75 + 25 = 100. Heavy fraction = 25 / 100 = 0.25. Mean = 0.75 × 34.968852682 + 0.25 × 36.965902602 = 35.468115162 u. The coefficients shown are rounded; calculation uses the full fractions.

02550751003435363738Relative signal (%) — nominal isotope peaks, fixed scalesReference mass (u); dashed: weighted mean; band: absolute boundMean 35.468115 u is a sample average, not a third isotope.

For bound 0, each nonnegative underlying signal lies within its stated interval. Heavy fraction lies in [0.25, 0.25], and mean in [35.468115162, 35.468115162] u. Bounds use low-heavy/high-light and high-heavy/low-light endpoints. They are conditional absolute ranges, not confidence intervals. A zero entered bound is an exact teaching-signal assumption, not zero real instrument uncertainty.

NIST reference masses: 34.968852682(37) and 36.965902602(55) u; parenthetical digits belong to the source uncertainty notation, not this synthetic signal bound. CIAAW’s inspected 2024 table gives natural chlorine-35 fraction 0.755–0.761 and chlorine-37 fraction 0.239–0.245. The synthetic 75/25 record is not that representative natural sample. Replaying it is not another measurement.

NIST chlorine isotope masses and composition · inspected 2026-10-28

CIAAW isotopic compositions (2024 table) · inspected 2026-10-28

Weighted mean 35.468115 u under equal response.

Signals are original synthetic records; reference isotope masses are source-linked. Doubling every signal does not change the normalized fractions. The mean is not the mass of a third isotope.

Captures preserve original synthetic signal settings and fixed source isotope masses. Replay recomputes conditional fractions and means, not measured sample composition.

Understand

A spectrum answers a declared particle question

Imagine two peaks from a sample containing one element. The taller peak represents more signal, but its height alone does not tell you an absolute atom count. We need to know which species produced each peak, how the instrument responds to them and how the signals were normalized.

This investigation stipulates singly charged monatomic chlorine ions and equal response for the two isotopes. The integer labels 35 and 37 are mass numbers, counting protons plus neutrons. They are not exact isotope masses. The table uses selected NIST reference neutral-atom masses, while the schematic places peaks at nominal isotope positions. At this display resolution we neglect the small electron-mass difference between atom and ion. These are different levels of numerical precision, not contradictory definitions.

Chlorine isotopes share 17 protons but have different neutron counts. A charged particle can also differ in electron count without changing its isotope. Return to atoms, isotopes and ions if those distinctions are unclear. The required spectrum stays with one element and singly charged monatomic ions; molecular fragments and mixed-element spectra require additional interpretation and are outside this opening task.

Normalize before averaging

The original synthetic signals 75 and 25 have total 100. Their fractions are 75/100 = 0.75 and 25/100 = 0.25. Both are dimensionless and add to one. Signals 750 and 250 have total 1000 and give the same fractions. A common sensitivity multiplier changes total intensity but cancels in the normalized ratio.

The weighted mean uses isotope masses, not just their integer labels:

Mean mass = 0.75 × 34.968852682 + 0.25 × 36.965902602 = 35.468115162 u.

Here u is the unified atomic mass unit. Read the calculation as “three quarters of the lighter reference mass plus one quarter of the heavier reference mass.” The mean must lie between the two masses. It is a property of this stipulated sample composition, not a third isotope whose atoms all have that mass. A typical periodic-table atomic-weight entry is also not a claim that every possible sample has exactly one isotope ratio.

Capture the original and scaled signals. Compare the total, both fractions and mean, then explain what changed. At each pure-isotope endpoint the mean equals the surviving isotope’s reference mass. With no signal, 0/0 is undefined: no fraction or mass estimate follows. Zero signal does not mean zero-mass atoms or proven absence of the element without a detection model.

Keep signal bounds separate from probabilities

For the 75:25 record, turn on an absolute bound of one signal unit per channel. The underlying lighter signal is in [74,76] and heavier signal in [24,26]. The smallest heavy fraction uses low-heavy and high-light values: 24/(76+24) = 0.24. The largest uses high-heavy and low-light: 26/(74+26) = 0.26. Shared normalization matters; changing one channel changes the denominator too.

The corresponding conditional mass interval is [35.4481446628,35.4880856612] u. This is an endpoint calculation under the declared bounds and equal-response assumption. It is not a 95% confidence interval: no repeated-sampling distribution was supplied. Applying the same absolute one-unit bound to 750:250 gives a narrower fractional range because the signal is larger relative to that bound; it does not establish that a real instrument has this error model.

A chosen zero bound means exact synthetic signals in this exercise. It does not erase the source reference-mass uncertainty or claim that real detector measurements are exact. The displayed mass digits expose the calculation; they should not be mistaken for the practical precision of a physical assay.

Source evidence and sample limits

The NIST chlorine table supplies the selected isotope masses and source uncertainty notation. The CIAAW isotopic-composition table, inspected on 28 October 2026 and labeled 2024, reports ranges for natural chlorine isotope fractions. The table in the widget states those ranges. The synthetic 75:25 record is deliberately not presented as the representative natural ratio or as a measured mass spectrum.

The source masses and simulated detector signals have distinct provenance. Replaying the same settings creates no independent measurement. If relative sensitivity were unknown or different between isotope channels, normalized signal alone would not establish isotope fractions. State that limitation without inventing corrections that were not measured.

Apply to a changed record

Before checking the result, analyze a new original pair: lighter signal 60, heavier signal 40. State the heavy fraction, weighted mean and the effect of changing both signals to 6 and 4. Sketch the mean between the reference masses and defend why it moves toward the heavier isotope.

Check the changed-record reasoning

The heavy fraction is 0.40; common rescaling leaves it unchanged. The mean is 0.60 × 34.968852682 + 0.40 × 36.965902602 = 35.767672650 u. This is a larger mean because the heavier isotope’s weight increased, not because either isotope changed its mass. Both records remain conditional on the same species and response assumptions.

In your reflection, include raw signals, normalization, units, an interval interpretation and a limitation. Continue to composition and identifiability to examine a different inference problem. These are different supplied samples; do not merge them into one unknown analysis.

Apply

Under equal isotope response, signals 75 and25 are replaced by 750 and250. The inferred heavy-isotope fraction is:

Public practice checks a specific claim. It does not establish independent mastery.

Show the normalized weighted sum and the bounded interval. Explain why the result is neither the mass of a third isotope nor a universal natural chlorine composition. Supply a changed-ratio calculation.

Continue

Completion requires a saved prediction, at least one capture and a reflection. Presence checks do not grade your reasoning.

Skipping retains experiments and awards no mastery.

Save a science backup or import one

Science work is stored locally in this browser, separately from mathematics and AI. It does not sync automatically. Use this science-only backup; this checkout's older all-subject export does not include science.

A legacy file is available only when the complete snapshot fits the 36 MB limit. For larger snapshots, prepare a complete file set below; never discard notebooks to make a smaller file.

Matching imported notebook drafts replace their current drafts. Omitted lessons and known first attempts remain. Export your current work first if you want to retain both drafts.

Complete file sets and course backups

A file set can hold more work than one science file. Keep its manifest and every part together. Each file is limited to 36 MB. This format needs this version of LearnAI or a compatible newer version; older versions can use only the legacy single-file backup above.

The set includes every saved science course and global continuation at this moment. Later edits need a new export. A conflicting tab exports its own visible work, which may differ from saved work in another tab.

0 file(s) selected. File order and filenames do not determine identity. Missing, changed or conflicting parts block the entire restore; no good part is applied by itself.

Science storage: loading. No account or remote computation is required.