Use the chain rule to audit an oscillator clock
Distinguish a phase shift from a rescaled time axis in a synthetic motion record.
Learning outcome: Compare phase indices0 and1 at gain1, then hold phase fixed while changing gain. Derive first and second derivatives in both time coordinates. Retain a same-physical-instant comparison and propose an independent clock or force/mass check that could distinguish the alternatives.
Starting recap
Derive the restoring equation, retain initial conditions and distinguish exact harmonic results from approximation and calibration assumptions.
All lessons are open directly. Your saved experiments remain when you leave and return.
Try
With phi=0 and g=1.2, indicated omega=5/3 rad/reported s and indicated period=1.2pi. First derivatives are scaled by5/6 and second derivatives by25/36. Neither scaling changes the assigned true amplitude .4 m.
Open the experimentPredict
Can an exact sinusoidal record alone calibrate its own time unit?
Experiment
Compare phase indices0 and1 at gain1, then hold phase fixed while changing gain. Derive first and second derivatives in both time coordinates. Retain a same-physical-instant comparison and propose an independent clock or force/mass check that could distinguish the alternatives.
Audit phase derivatives against a timestamp gain
Worked teaching model · synthetic values · True synthetic x=.4 cos(2t+phi) m; displayed clock u=gain*t. Gain is a known intervention, not inferred from waveform alone. Compare true and reported-time derivatives at true t=.5 s; no noise.
Reset keeps your prediction, captures and practice history.
Position against reported clock
Axes rescale independently. Curves join sampled coordinates; a joining segment is not additional measured evidence. Read physical units rather than screen angles or apparent slopes.
Position against reported clock: numerical coordinates
| reported time (s) | displacement (m) |
|---|---|
| 0 | 0.282843 |
| 0.0523599 | 0.251728 |
| 0.10472 | 0.217856 |
| 0.15708 | 0.181596 |
| 0.20944 | 0.143347 |
| 0.261799 | 0.103528 |
| 0.314159 | 0.0625738 |
| 0.366519 | 0.0209344 |
| 0.418879 | -0.0209344 |
| 0.471239 | -0.0625738 |
| 0.523599 | -0.103528 |
| 0.575959 | -0.143347 |
| 0.628319 | -0.181596 |
| 0.680678 | -0.217856 |
| 0.733038 | -0.251728 |
| 0.785398 | -0.282843 |
| 0.837758 | -0.310858 |
| 0.890118 | -0.335468 |
| 0.942478 | -0.356403 |
| 0.994838 | -0.373432 |
| 1.0472 | -0.38637 |
| 1.09956 | -0.395075 |
| 1.15192 | -0.399452 |
| 1.20428 | -0.399452 |
| 1.25664 | -0.395075 |
| 1.309 | -0.38637 |
| 1.36136 | -0.373432 |
| 1.41372 | -0.356403 |
| 1.46608 | -0.335468 |
| 1.51844 | -0.310858 |
| 1.5708 | -0.282843 |
| 1.62316 | -0.251728 |
| 1.67552 | -0.217856 |
| 1.72788 | -0.181596 |
| 1.78024 | -0.143347 |
| 1.8326 | -0.103528 |
| 1.88496 | -0.0625738 |
| 1.93732 | -0.0209344 |
| 1.98968 | 0.0209344 |
| 2.04204 | 0.0625738 |
| 2.0944 | 0.103528 |
| 2.14675 | 0.143347 |
| 2.19911 | 0.181596 |
| 2.25147 | 0.217856 |
| 2.30383 | 0.251728 |
| 2.35619 | 0.282843 |
| 2.40855 | 0.310858 |
| 2.46091 | 0.335468 |
| 2.51327 | 0.356403 |
| 2.56563 | 0.373432 |
| 2.61799 | 0.38637 |
| 2.67035 | 0.395075 |
| 2.72271 | 0.399452 |
| 2.77507 | 0.399452 |
| 2.82743 | 0.395075 |
| 2.87979 | 0.38637 |
| 2.93215 | 0.373432 |
| 2.98451 | 0.356403 |
| 3.03687 | 0.335468 |
| 3.08923 | 0.310858 |
| 3.14159 | 0.282843 |
| Quantity | Value | Unit |
|---|---|---|
| Phase | 0.785398 | rad |
| Physical displacement at selected instant | -0.0851834 | m |
| True velocity at selected instant | -0.781649 | m/s |
| Reported-time first derivative | -0.781649 | m/reported s |
| True acceleration at selected instant | 0.340733 | m/s² |
| Reported-time second derivative | 0.340733 | m/reported s² |
| Indicated angular frequency | 2 | rad/reported s |
| Indicated period | 3.14159 | reported s |
A clock gain rescales inferred derivative rates even when every position lies on a smooth periodic curve.
Chain rule gives dx/du=(dx/dt)/gain and d²x/du²=(d²x/dt²)/gain². A waveform alone determines frequency in its reported time unit, not an independently calibrated physical clock. Known k/m or an independent timing standard is needed to distinguish a clock error from a genuinely changed oscillator.
Derive before checking. Retain contrasting captures and explain one assumption that could fail; calculated evidence is not actual laboratory work.
A clock gain rescales inferred derivative rates even when every position lies on a smooth periodic curve.
Chain rule gives dx/du=(dx/dt)/gain and d²x/du²=(d²x/dt²)/gain². A waveform alone determines frequency in its reported time unit, not an independently calibrated physical clock. Known k/m or an independent timing standard is needed to distinguish a clock error from a genuinely changed oscillator.
Captures preserve recipes and replay their calculated results. They are synthetic model evidence, not physical measurements.
Understand
Apply
Public practice checks a specific claim. It does not establish independent mastery.
Why is a quarter-cycle phase shift not equivalent to a multiplicative clock gain?
Continue
Completion requires a saved prediction, at least one capture and a reflection. Presence checks do not grade your reasoning.
Skipping retains experiments and awards no mastery.
Save a science backup or import one
Science work is stored locally in this browser, separately from mathematics and AI. It does not sync automatically. Use this science-only backup; this checkout's older all-subject export does not include science.
A legacy file is available only when the complete snapshot fits the 36 MB limit. For larger snapshots, prepare a complete file set below; never discard notebooks to make a smaller file.
Matching imported notebook drafts replace their current drafts. Omitted lessons and known first attempts remain. Export your current work first if you want to retain both drafts.
Complete file sets and course backups
A file set can hold more work than one science file. Keep its manifest and every part together. Each file is limited to 36 MB. This format needs this version of LearnAI or a compatible newer version; older versions can use only the legacy single-file backup above.
The set includes every saved science course and global continuation at this moment. Later edits need a new export. A conflicting tab exports its own visible work, which may differ from saved work in another tab.
0 file(s) selected. File order and filenames do not determine identity. Missing, changed or conflicting parts block the entire restore; no good part is applied by itself.
Science storage: loading. No account or remote computation is required.