Distinguish arterial storage from mean perfusion
Elastic arteries store some ejected volume as their walls expand and return it during the interval between ventricular ejections. Resistance and compliance are distinct properties: resistance links pressure drop to flow, while compliance links stored volume change to pressure change. A reservoir description can explain smoothing of pulsatile input without resolving every traveling wave in the arterial tree.
Learning outcome: Compare all compliances at period 1, then change period at fixed compliance. Retain peak, trough, mean and integrated outflow, distinguishing the instantaneous pulse from the displayed runoff segment.
Starting recap
Trace cardiovascular and respiratory anatomy, conserve pressure-flow and gas-content ledgers, and distinguish transport, storage, binding and feasible uptake under explicitly supplied nonclinical boundaries.
All lessons are open directly. Your saved experiments remain when you leave and return.
Try
At C=2 and T=1, pressure jump is 3 and time constant 4. Peak is 3/[1−e^(−1/4)]≈13.5624, trough≈10.5624, mean pressure 12 and mean flow 6. Stored-volume decrease C(Pmax−Pmin)=6 closes the period.
Open the experimentPredict
Can greater compliance reduce pulsatility without reducing the specified mean flow?
Experiment
Compare all compliances at period 1, then change period at fixed compliance. Retain peak, trough, mean and integrated outflow, distinguishing the instantaneous pulse from the displayed runoff segment.
Separate arterial compliance from mean flow and pulse size
Worked teaching model · synthetic values · Original linear reservoir with downstream pressure 0, resistance 2 pressure·time/volume and instantaneous volume input 6 each period b. At periodic steady state Pmax=(6/C)/(1−exp(−T/(2C))), Pmin=Pmax exp(−T/(2C)). Between pulses dP/dt=−P/(2C); not a clinical waveform.
Reset keeps your prediction, captures and practice history.
Compliance changes pulse size and decay while mean flow is set by input volume per period.
The plot shows the between-pulse segment only; the next instantaneous pulse adds 6/C pressure. This linear reservoir neglects wave propagation, nonlinear compliance and active regulation and is not a person’s pressure trace.
| Time since instantaneous pulse | Reservoir pressure |
|---|---|
| 0 | 13.56243 |
| 0.05000000 | 13.39396 |
| 0.1000000 | 13.22758 |
| 0.1500000 | 13.06326 |
| 0.2000000 | 12.90099 |
| 0.2500000 | 12.74073 |
| 0.3000000 | 12.58246 |
| 0.3500000 | 12.42616 |
| 0.4000000 | 12.27180 |
| 0.4500000 | 12.11936 |
| 0.5000000 | 11.96881 |
| 0.5500000 | 11.82013 |
| 0.6000000 | 11.67330 |
| 0.6500000 | 11.52829 |
| 0.7000000 | 11.38508 |
| 0.7500000 | 11.24365 |
| 0.8000000 | 11.10398 |
| 0.8500000 | 10.96605 |
| 0.9000000 | 10.82982 |
| 0.9500000 | 10.69529 |
| 1 | 10.56243 |
| Quantity | Value | Unit |
|---|---|---|
| Pressure just after pulse | 13.56243 | pressure units |
| Pressure just before next pulse | 10.56243 | pressure units |
| Pulse pressure difference | 3 | pressure units |
| Mean flow | 6 | volume/time |
| Mean pressure | 12 | pressure units |
| Runoff time constant | 4 | time units |
| Outflow integrated over one period | 6 | volume units |
Original instructional diagrams and parameters, not individual physiological measurements, safety limits or treatment guidance.
Compliance changes pulse size and decay while mean flow is set by input volume per period.
The plot shows the between-pulse segment only; the next instantaneous pulse adds 6/C pressure. This linear reservoir neglects wave propagation, nonlinear compliance and active regulation and is not a person’s pressure trace.
Captures preserve recipes and replay their calculated results. They are synthetic model evidence, not physical measurements.
Understand
Apply
Public practice checks a specific claim. It does not establish independent mastery.
At C=1 and T=2, find pulse difference, mean flow, mean pressure and runoff time constant.
Continue
Completion requires a saved prediction, at least one capture and a reflection. Presence checks do not grade your reasoning.
Skipping retains experiments and awards no mastery.
Save a science backup or import one
Science work is stored locally in this browser, separately from mathematics and AI. It does not sync automatically. Use this science-only backup; this checkout's older all-subject export does not include science.
A legacy file is available only when the complete snapshot fits the 36 MB limit. For larger snapshots, prepare a complete file set below; never discard notebooks to make a smaller file.
Matching imported notebook drafts replace their current drafts. Omitted lessons and known first attempts remain. Export your current work first if you want to retain both drafts.
Complete file sets and course backups
A file set can hold more work than one science file. Keep its manifest and every part together. Each file is limited to 36 MB. This format needs this version of LearnAI or a compatible newer version; older versions can use only the legacy single-file backup above.
The set includes every saved science course and global continuation at this moment. Later edits need a new export. A conflicting tab exports its own visible work, which may differ from saved work in another tab.
0 file(s) selected. File order and filenames do not determine identity. Missing, changed or conflicting parts block the entire restore; no good part is applied by itself.
Science storage: loading. No account or remote computation is required.