Derive the aperture transform and its central limit
Fraunhofer diffraction adds contributions from every point of an aperture with position-dependent phase. For uniform monochromatic illumination and a scalar far-field approximation, a point x across a slit contributes exp(i2πux), where u=sinθ/λ. This spatial frequency has inverse-length units; it is not automatically an angle.
Learning outcome: Integrate cosine across the aperture independently, verify the central limit and sign of successive amplitude lobes, then compare width changes without confusing normalized shape with power.
Starting recap
Retain complex amplitude before intensity, definite-integral boundaries, normalization, calibration covariance and unused evidence.
All lessons are open directly. Your saved experiments remain when you leave and return.
Try
At w=2 and u=0.25, πwu=π/2. Field amplitude is 2/π≈0.636620 and intensity 4/π²≈0.405285. The first zero lies at u=0.5 and the central lobe spans width 1 in inverse reference length.
Open the experimentPredict
Why is the central intensity finite even though the quotient contains u in its denominator?
Experiment
Integrate cosine across the aperture independently, verify the central limit and sign of successive amplitude lobes, then compare width changes without confusing normalized shape with power.
Integrate a rectangular aperture amplitude
Worked teaching model · synthetic values · Uniform scalar aperture, normal monochromatic illumination, Fraunhofer observation. Normalized field is (1/w)∫ exp(i2πu x)dx over −w/2..w/2. Central normalization removes width-dependent throughput; it is not total collected power.
Reset keeps your prediction, captures and practice history.
Integrate the field across the aperture before taking its squared magnitude; the central limit is exactly one.
Uniform scalar aperture, normal monochromatic illumination, Fraunhofer observation. Normalized field is (1/w)∫ exp(i2πu x)dx over −w/2..w/2. Central normalization removes width-dependent throughput; it is not total collected power.
The vertical axis is rescaled to this case’s actual range; equal display height does not imply equal optical power. The finite curve is illustrative; the ledger preserves the exact case values and stated numerical quadrature.
| Quantity | Value | Unit |
|---|---|---|
| Aperture phase half-span | 1.57080 | radians |
| Normalized signed real amplitude | 0.636620 | ratio |
| Normalized intensity | 0.405285 | ratio |
| First positive zero | 0.500000 | inverse reference length |
| Central lobe zero-to-zero width | 1 | inverse reference length |
Virtual original records only. No laser, intense-light source, instrument alignment, physical apparatus operation or completed practical competence is supplied.
Integrate the field across the aperture before taking its squared magnitude; the central limit is exactly one.
Uniform scalar aperture, normal monochromatic illumination, Fraunhofer observation. Normalized field is (1/w)∫ exp(i2πu x)dx over −w/2..w/2. Central normalization removes width-dependent throughput; it is not total collected power.
Captures preserve recipes and replay their calculated results. They are synthetic model evidence, not physical measurements.
Understand
Apply
Public practice checks a specific claim. It does not establish independent mastery.
Use w=3 and u=0.5. Find amplitude, intensity and first positive zero.
Continue
Completion requires a saved prediction, at least one capture and a reflection. Presence checks do not grade your reasoning.
Skipping retains experiments and awards no mastery.
Save a science backup or import one
Science work is stored locally in this browser, separately from mathematics and AI. It does not sync automatically. Use this science-only backup; this checkout's older all-subject export does not include science.
A legacy file is available only when the complete snapshot fits the 36 MB limit. For larger snapshots, prepare a complete file set below; never discard notebooks to make a smaller file.
Matching imported notebook drafts replace their current drafts. Omitted lessons and known first attempts remain. Export your current work first if you want to retain both drafts.
Complete file sets and course backups
A file set can hold more work than one science file. Keep its manifest and every part together. Each file is limited to 36 MB. This format needs this version of LearnAI or a compatible newer version; older versions can use only the legacy single-file backup above.
The set includes every saved science course and global continuation at this moment. Later edits need a new export. A conflicting tab exports its own visible work, which may differ from saved work in another tab.
0 file(s) selected. File order and filenames do not determine identity. Missing, changed or conflicting parts block the entire restore; no good part is applied by itself.
Science storage: loading. No account or remote computation is required.