Distinguish a maintained compartment gradient from equilibrium
A compartment can maintain a stable composition while material continuously enters and leaves. This steady state differs from equilibrium: an energy-coupled pump can oppose a leak so that net accumulation is zero even though each one-way flux is nonzero. A constant pH reading therefore does not prove that transport has stopped.
Learning outcome: Hold pump4 and compare additional leak1 and3. Verify that outward leak equals the supplied inward pump in both states, while pH differences differ. Explain why balanced fluxes do not imply thermodynamic equilibrium.
Starting recap
Connect calibrated dimensions, cell organization, material balance and membrane energetics. State the model boundary before interpreting a changed condition.
All lessons are open directly. Your saved experiments remain when you leave and return.
Try
Pump4 and total leak coefficient2 giveΔpH=2, compartmentpH5 and a100-fold hydrogen-ion ratio relative to cytosolpH7. Increasing total leak coefficient to4 at the same pump givesΔpH1, compartmentpH6 and a10-fold ratio. Both states can have nonzero opposing fluxes.
Open the experimentPredict
Can increasing leak change the steady gradient even if the pump continues at the same rate?
Experiment
Hold pump4 and compare additional leak1 and3. Verify that outward leak equals the supplied inward pump in both states, while pH differences differ. Explain why balanced fluxes do not imply thermodynamic equilibrium.
Balance a compartment pump against a leak
Worked teaching model · synthetic values · Phenomenological steady-state acidification: pump=b; outward leak=(1+a)ΔpH, so ΔpH=b/(1+a), cytosolpH7. Constant effective buffering and pump flux are stipulated, not a mechanistic proton-current law. No membrane voltage, ATP budget or time course is inferred.
Reset keeps your prediction, captures and practice history.
A steady gradient can require continuous opposing fluxes; a steady state is not equilibrium.
Pump and leak magnitudes balance while a nonzero gradient remains. Increasing leak lowers the gradient at fixed pump. The linear leak-versus-ΔpH relation is phenomenological; it is not a physical proton conductance law or a derived ATP stoichiometry.
| Quantity | Value | Unit |
|---|---|---|
| Steady-state pH difference | 2 | pH units |
| Compartment pH | 5 | pH |
| Compartment/cytosol hydrogen-ion ratio | 100 | ratio |
| Outward leak at steady state | 4 | relative flux units |
| Supplied inward pump | 4 | relative flux units |
Retain prior predictions, settings and quantities in the notebook. These are original supplied/calculated comparisons, not physical specimen observations or laboratory participation.
A steady gradient can require continuous opposing fluxes; a steady state is not equilibrium.
Pump and leak magnitudes balance while a nonzero gradient remains. Increasing leak lowers the gradient at fixed pump. The linear leak-versus-ΔpH relation is phenomenological; it is not a physical proton conductance law or a derived ATP stoichiometry.
Captures preserve recipes and replay their calculated results. They are synthetic model evidence, not physical measurements.
Understand
Apply
Public practice checks a specific claim. It does not establish independent mastery.
In the same phenomenological model, pump3 and total leak coefficient1.5 maintain a compartment against cytosolicpH7. FindΔpH, compartmentpH and hydrogen-ion ratio.
Continue
Completion requires a saved prediction, at least one capture and a reflection. Presence checks do not grade your reasoning.
Skipping retains experiments and awards no mastery.
Save a science backup or import one
Science work is stored locally in this browser, separately from mathematics and AI. It does not sync automatically. Use this science-only backup; this checkout's older all-subject export does not include science.
A legacy file is available only when the complete snapshot fits the 36 MB limit. For larger snapshots, prepare a complete file set below; never discard notebooks to make a smaller file.
Matching imported notebook drafts replace their current drafts. Omitted lessons and known first attempts remain. Export your current work first if you want to retain both drafts.
Complete file sets and course backups
A file set can hold more work than one science file. Keep its manifest and every part together. Each file is limited to 36 MB. This format needs this version of LearnAI or a compatible newer version; older versions can use only the legacy single-file backup above.
The set includes every saved science course and global continuation at this moment. Later edits need a new export. A conflicting tab exports its own visible work, which may differ from saved work in another tab.
0 file(s) selected. File order and filenames do not determine identity. Missing, changed or conflicting parts block the entire restore; no good part is applied by itself.
Science storage: loading. No account or remote computation is required.