Infer wavelength while testing geometry and calibration assumptions
A fringe pattern can support an inference only after its coordinate references and geometry are stated. The synthetic packet uses signed orders −3 through +3, slit separation 0.25 mm and screen distance 1.20 m. Exact generated positions use y=L tan(arcsin(mλ/d)), then add a common coordinate offset and a small declared reading error. The source wavelength is available for testing the model, not because a real instrument has been calibrated.
Learning outcome: Compare offsets −2, 0 and +2 mm at one wavelength; retain slope, intercept and the symmetric estimate. Then change wavelength and freeze a fourth-order prediction before reading its ledger value. Explain which calibration errors this comparison can and cannot remove.
Starting recap
Distinguish spatial and temporal axes, signed disturbances, material boundaries and exact versus approximate wave geometry. Identify supplied numerical enrichment before applying it.
All lessons are open directly. Your saved experiments remain when you leave and return.
Try
For true 550 nm with a +1 mm common offset, the original noisy packet gives fitted slope about 2.63647 mm/order and intercept 1.00000 mm, hence paraxial λ≈549.27 nm. Its fourth-order prediction is 11.54589 mm, while the unperturbed held-out exact coordinate is 11.56041 mm. The difference is small but not silently zero.
Open the experimentPredict
Will adding the same coordinate offset to every order change a free-intercept spacing slope?
Experiment
Compare offsets −2, 0 and +2 mm at one wavelength; retain slope, intercept and the symmetric estimate. Then change wavelength and freeze a fourth-order prediction before reading its ledger value. Explain which calibration errors this comparison can and cannot remove.
Infer wavelength while challenging position references
Worked teaching model · synthetic values · Original synthetic slit separation 0.25 mm and screen distance 1.20 m. Orders −3 through +3 use exact geometry, common offset and stated fixed reading errors. Fit position versus signed order, compare symmetric spacings and hold out order 4. No actual wavelength calibration certified.
Reset keeps your prediction, captures and practice history.
Original calibration packet
- 1: synthetic observations — points
- 2: fitted paraxial line — long dashes
Accessible coordinates for this panel
These tables sample up to 82 displayed coordinates per series, including both endpoints. Fine curves may contain additional calculated points between table entries; use the ledger for exact analytic minima, frequencies or other named evidence. Values are synthetic, not instrument readings.
| signed interference order | screen coordinate (mm) |
|---|---|
| -3 | -6.9002 |
| -2 | -4.2901 |
| -1 | -1.63 |
| 0 | 1 |
| 1 | 3.63 |
| 2 | 6.2901 |
| 3 | 8.9002 |
| signed interference order | screen coordinate (mm) |
|---|---|
| -3 | -6.9094 |
| -2 | -4.2729 |
| -1 | -1.6365 |
| 0 | 1 |
| 1 | 3.6365 |
| 2 | 6.2729 |
| 3 | 8.9094 |
Each plot rescales independently. Compare values and units rather than apparent screen angles. Different panels can represent different quantities and are not silently overlaid.
| Quantity | Value | Unit |
|---|---|---|
| Fitted position-order slope | 2.6365 | mm/order |
| Fitted coordinate intercept | 1 | mm |
| Paraxial inferred wavelength | 549.27 | nm |
| Symmetric outer-order wavelength estimate | 548.62 | nm |
| Held-out order 4 exact coordinate | 11.56 | mm |
| Fit-predicted order 4 coordinate | 11.546 | mm |
A common coordinate offset changes the intercept but cancels from symmetric separations and a free-intercept slope.
The fit is paraxial while the original geometry uses tangent and inverse sine. Fixed reading errors are [+.02,−.01,+.01,0,−.01,+.01,−.02] mm in increasing order. Neither small residuals nor cancellation of the coordinate zero establishes the slit separation or screen-distance calibration. Hold out order 4 and compare an uncertainty interval, not an unjustified exact match.
A common coordinate offset changes the intercept but cancels from symmetric separations and a free-intercept slope.
The fit is paraxial while the original geometry uses tangent and inverse sine. Fixed reading errors are [+.02,−.01,+.01,0,−.01,+.01,−.02] mm in increasing order. Neither small residuals nor cancellation of the coordinate zero establishes the slit separation or screen-distance calibration. Hold out order 4 and compare an uncertainty interval, not an unjustified exact match.
Captures preserve recipes and replay their calculated results. They are synthetic model evidence, not physical measurements.
Understand
Apply
Public practice checks a specific claim. It does not establish independent mastery.
Why is agreement of two offset-canceling methods not independent verification of the slit-separation value they both use?
Continue
Completion requires a saved prediction, at least one capture and a reflection. Presence checks do not grade your reasoning.
Skipping retains experiments and awards no mastery.
Save a science backup or import one
Science work is stored locally in this browser, separately from mathematics and AI. It does not sync automatically. Use this science-only backup; this checkout's older all-subject export does not include science.
A legacy file is available only when the complete snapshot fits the 36 MB limit. For larger snapshots, prepare a complete file set below; never discard notebooks to make a smaller file.
Matching imported notebook drafts replace their current drafts. Omitted lessons and known first attempts remain. Export your current work first if you want to retain both drafts.
Complete file sets and course backups
A file set can hold more work than one science file. Keep its manifest and every part together. Each file is limited to 36 MB. This format needs this version of LearnAI or a compatible newer version; older versions can use only the legacy single-file backup above.
The set includes every saved science course and global continuation at this moment. Later edits need a new export. A conflicting tab exports its own visible work, which may differ from saved work in another tab.
0 file(s) selected. File order and filenames do not determine identity. Missing, changed or conflicting parts block the entire restore; no good part is applied by itself.
Science storage: loading. No account or remote computation is required.