SCIENCE · INVESTIGATE AND EXPLAIN

Explain voltage sag inside a source

Separate emf, terminal voltage, load power and internal dissipation.

Learning outcome: Calculate a loaded source operating point and reconcile delivered and internally dissipated power.

Starting recap

A source can be represented by an ideal emf in series with internal resistance. Emf has voltage units, despite its historical name.

All lessons are open directly. Your saved experiments remain when you leave and return.

Try

Why can a source labeled 6 V deliver less than 6 V across a connected load?

Open the experiment

Predict

With internal resistance 40 Ω, predict whether reducing load resistance from 500 to 100 Ω raises or lowers current and terminal voltage.

Experiment

Capture 500 and 100 Ω loads at 40 Ω internal resistance. Inspect the source/load intersection and power ledger. Set internal resistance to zero to recover an ideal source.

Find the operating point of a nonideal source

Worked teaching model · synthetic values · Steady discharge model: fixed 6 V emf in series with a constant internal resistance r and one ohmic load R. Wires and meters are ideal. Source emf and both resistances stay fixed within each scenario. No chemistry, depletion, recharge, thermal dynamics, current limiter or switching transient. Power is energy per time, not stored capacity or temperature. Efficiency is load power divided by emf-source output within this model only. Characteristic lines include theoretical points outside the selectable loads; the zero-current intercept is an unloaded limit, not a measured open-circuit experiment. No short-circuit control is provided.

Reset keeps your prediction, captures and practice history.

Source model boundary+−emf = 6 Vr = 40 ΩDrop 1.000 VR = 200 ΩLoad 0.1250 W+−Terminal voltage 5.000 VSame current 25.000 mADotted terminal span is a measurement annotation, not a wire
One operating point satisfies both relations · terminal voltage (V)01234560102030405060Current (mA) · solid: source · dashed: load · dot: selected intersectionLines include theoretical values outside the selectable load settings
Power and voltage accounting
QuantityValueInterpretation
Emf6.000 VIdeal conversion energy per charge
Terminal voltage5.000 VVoltage across the external load
Internal drop1.000 VCurrent times internal resistance
Emf-source power0.1500 W6 V times current
Load power0.1250 WDelivered outside source boundary
Internal power0.0250 WDissipated inside source boundary
Load power fraction83.33%Load power / emf-source power; not battery capacity
Same source with five different loads
Load (Ω)Current (mA)Terminal (V)Load power (W)Internal power (W)Load fraction (%)
10042.8574.2860.18370.073571.43
20025.0005.0000.12500.025083.33
30017.6475.2940.09340.012588.24
40013.6365.4550.07440.007490.91
50011.1115.5560.06170.004992.59

Current 25.000 mA; terminal voltage 5.000 V; internal drop 1.000 V.

Emf source supplies 0.1500 W = load 0.1250 W + internal dissipation 0.0250 W. Load fraction 83.33%. This fraction does not predict battery life.

Captures preserve recipes and replay their calculated results. They are synthetic model evidence, not physical measurements.

Understand

The source has an inside and an outside

A source labeled 6 V need not maintain 6 V while delivering current. Here an ideal emf of 6 V sits in series with an internal resistance r and an external load R. Emf is energy supplied per charge, measured in volts, not a mechanical force. Terminal voltage is the potential difference across the source’s external terminals, also across the load in this circuit.

The dashed boundary contains the ideal source and internal resistor. The dotted span between terminals is a voltage-measurement annotation, not a wire that shorts them. Real internal resistance can summarize several physical effects; the drawing does not claim there is a removable resistor inside every battery.

Find one point that satisfies two conditions

The source relation is V terminal = emf − I r. The load relation is V terminal = I R. Here I is discharge current in amperes, R and r are resistances in ohms, and all voltage terms are in volts. Combining them gives I = emf/(R + r). These steady-state relations are developed in OpenStax: electromotive force.

The solid source line slopes downward as current increases; the dashed load line slopes upward. Their intersection is the state satisfying both equations. The graph keeps the same 0–60 mA and 0–6 V scales. It is a relation between possible states, not a trace of a source changing over time. Line segments include theoretical states outside the selectable load presets.

At the default R = 200 Ω and r = 40 Ω, current is 6/240 = 0.025 A = 25 mA. The internal drop is 0.025 × 40 = 1 V, leaving 5 V across the load. Check that the point lies on both lines, then explain why using 6/200 would overestimate this current.

Change the load, keeping the source model fixed

Before moving the load slider, predict both current and terminal voltage at the two extremes with r = 40 Ω.

LoadCurrentTerminal voltage
500 Ω11.111 mA5.556 V
100 Ω42.857 mA4.286 V

Capture both. Lower load resistance draws more current, causing a larger internal drop. Terminal voltage falls even though the emf stays at 6 V. Returning to the original setting returns the same calculation: this model has no depletion or history.

Now set r = 0. The source line becomes horizontal, terminal voltage is always 6 V for the allowed loads, and internal dissipation vanishes. This recovers the earlier ideal-source assumption. The zero-current intercept is an unloaded limit; no control opens the circuit or performs an actual open-circuit measurement.

Reconcile the power before discussing efficiency

At the default setting, emf-source power is (6 V)(0.025 A) = 0.150 W. The load receives (5 V)(0.025 A) = 0.125 W. Internal dissipation is I²r = (0.025)² × 40 = 0.025 W. The two destinations sum to source output. Energy is transferred and dissipated, not created or destroyed by the bookkeeping.

The load fraction is P load/P source = R/(R + r), or 83.33% at the default. This is the model’s electrical delivery efficiency, not battery capacity, lifetime or a complete chemical efficiency. At r = 0 it is 100% only because every modeled loss is absent.

With r = 40 Ω, increasing R from 100 to 500 Ω raises the fraction from 71.43% to 92.59%, while load power falls from approximately 0.1837 to 0.0617 W. A larger percentage does not necessarily deliver more useful power. The model cannot calculate a temperature rise from internal dissipation without a thermal model.

Transfer to another source

Outside the fixed-emf browser, suppose emf = 9 V, r = 50 Ω and R = 250 Ω. Calculate current, terminal voltage, load power, internal power and the load fraction.

Check the nonideal-source transfer

I = 9/300 = 0.030 A. Terminal voltage is 0.030 × 250 = 7.5 V, also 9 − 0.030 × 50. Load power is 0.225 W; internal power is 0.045 W; their sum is 0.270 W = 9 × 0.030. The load fraction is 0.225/0.270 = 83.33%. None of these values gives a discharge duration without information about stored energy and changing source behavior.

Apply

With fixed positive emf and internal resistance, lowering the positive load resistance makes:

Public practice checks a specific claim. It does not establish independent mastery.

Explain why terminal voltage can fall while current rises, and distinguish load fraction, load power and stored battery capacity.

Continue

Completion requires a saved prediction, at least one capture and a reflection. Presence checks do not grade your reasoning.

Skipping retains experiments and awards no mastery.

Save a science backup or import one

Science work is stored locally in this browser, separately from mathematics and AI. It does not sync automatically. Use this science-only backup; this checkout's older all-subject export does not include science.

A legacy file is available only when the complete snapshot fits the 36 MB limit. For larger snapshots, prepare a complete file set below; never discard notebooks to make a smaller file.

Matching imported notebook drafts replace their current drafts. Omitted lessons and known first attempts remain. Export your current work first if you want to retain both drafts.

Complete file sets and course backups

A file set can hold more work than one science file. Keep its manifest and every part together. Each file is limited to 36 MB. This format needs this version of LearnAI or a compatible newer version; older versions can use only the legacy single-file backup above.

The set includes every saved science course and global continuation at this moment. Later edits need a new export. A conflicting tab exports its own visible work, which may differ from saved work in another tab.

0 file(s) selected. File order and filenames do not determine identity. Missing, changed or conflicting parts block the entire restore; no good part is applied by itself.

Science storage: loading. No account or remote computation is required.