Learn

Learning preferences

Make learning more comfortable. Changes apply immediately.

Enlarges page content, including diagrams and their labels. You can also use your browser’s zoom.

Choose the colours that are easiest for you to distinguish. Applies to lesson diagrams and lab plots. Labels, shapes, hatching and line patterns also distinguish meanings. Source photographs and raw image brightness stay unchanged; mask-only views are available for image overlays.

ExampleComparisonSample link

Saved in this browser on this device. Preferences are separate from progress backups.

SCIENCE · INVESTIGATE AND EXPLAIN

Calculate Darcy flux and volumetric flow

Connect head drop and conductivity to flow while keeping flux distinct from pore-water velocity.

Learning outcome: Calculate signed Darcy flux and discharge with consistent units and interpret controlled conductivity comparisons.

Starting recap

Hydraulic conductivity K describes how readily the specified water and medium transmit flow under a head gradient. Its velocity units do not make it the water speed.

All lessons are open directly. Your saved experiments remain when you leave and return.

Try

K = 2 m/day and driving gradient 0.04 give q = 0.08 m/day; through 20 m² of bulk area, Q = 1.6 m³/day.

Open the experiment

Predict

Will doubling K at fixed boundary heads double the flow, change its direction, or both?

Experiment

At left head 14 m compare K = 2 and 4 m/day, then reverse the head drop with left head 6 m. Check signed q and Q using the fixed 20 m² cross-section.

Compare head, conductivity and groundwater flow

Worked teaching model · synthetic values · Synthetic steady, one-dimensional saturated column: length 100 m, bulk cross-section 20 m², effective porosity 0.25. Right hydraulic head is maintained at 10 m; the left head is adjustable relative to the same arbitrary datum. The column remains saturated by assumption. Uniform conductivity, constant-density water and laminar Darcy flow are assumed. Positive rates mean left to right. Hydraulic head is not terrain elevation or depth below ground. No recharge, pumping, transient storage, dispersion, diffusion or sorption is modeled.

Reset keeps your prediction, captures and practice history.

Hydraulic head (m) · common datum · calculated steady profile, not ground surface051015200255075100Distance from left endpoint (m) · fixed independent axis scalesLeft (circle): 14 m · Right (square): 10 m · Left to rightFlow follows decreasing hydraulic head; the line is not a water-particle trajectory
Signed rate (m/day) · positive: left → right · fixed shared scale-4-2024Darcy flux q = Q / bulk area (filled circle)Average pore-water velocity v = q / effective porosity (open square)At porosity 0.25, |v| is four times |q|; conductivity K is neither of these rates
Head, discharge and ideal advective travel
QuantityCalculation or conditionResult
Head drop left minus right14 − 104 m
Signed driving head drop / length(14 − 10) / 1000.040 m/m
Head slope dh/dx(10 − 14) / 100-0.040 m/m
Darcy flux q = −K dh/dx2 × 0.0400.080 m/day
Discharge Q = q A0.080 × 201.600 m³/day
Average pore-water velocity v0.080 / 0.250.320 m/day
Ideal advective transit100 / |v|; from higher-head endpoint312.50 days

Bulk volume is 2,000 m³; the assumed connected pore-water volume is 500 m³. Constant boundary heads maintain steady flow. Transit uses average pore velocity and excludes spreading, diffusion, sorption and changing conditions. Equal heads give zero net advective flow here, not a claim that all molecular motion stops.

Left to right. Discharge Q = 1.600 m³/day; Darcy flux q = 0.080 m/day.

Average pore-water velocity v = q / 0.25 = 0.320 m/day. Ideal 100 m advective transit from the higher-head endpoint: 312.50 days. This is a conditional water-transport calculation, not a contaminant arrival prediction or safe withdrawal estimate.

Captures preserve recipes and replay their calculated results. They are synthetic model evidence, not physical measurements.

Understand

Separate the driving gradient from the medium’s response

A head difference provides a driving gradient, but the resulting flow also depends on the water-transmitting properties of the medium. This investigation assigns hydraulic conductivity K between 1 and 10 m/day. The selected homogeneous column has the same conductivity everywhere, a fixed length of 100 m and a bulk cross-section of 20 m².

Hydraulic conductivity depends on the porous material and fluid properties. It has dimensions of length per time but is not, by itself, the speed of a water parcel. Darcy’s law relates it to flow through a specified area under a head gradient. USGS explanation of conductivity and Darcy’s law.

The fictional setup assumes saturated, constant-density, one-dimensional laminar flow. Boundary heads are maintained. No transient adjustment, pumping well, variable layering or unsaturated behavior is calculated.

Calculate flux before multiplying by area

Let i be the signed driving head drop divided by length: i = (left head − right head)/100 m. Darcy flux q is K × i, with positive flow to the right. This is equivalent to q = −K dh/dx when dh/dx means the mathematical slope of head toward increasing x.

At left head 14 m and right head 10 m, i = 4/100 = 0.04. With K = 2 m/day, q = 2 × 0.04 = 0.08 m/day. The gradient is a ratio of lengths, so its units cancel. The resulting flux has length-per-time units.

Flux is volume per time per unit bulk cross-sectional area. Multiplying q by the full 20 m² gives the signed volumetric flow Q = 1.6 m³/day. Write the unit multiplication: m/day × m² = m³/day. Q answers how much water crosses the whole section per day; q normalizes that amount by bulk area.

Why flux is not pore-water speed

The bulk area includes solids as well as connected pore space. Dividing flow by that whole area produces a flux, not the average speed within the effective flowing pore space. The investigation’s effective porosity is 0.25, so its average pore velocity is q/0.25. At the default, that is 0.32 m/day, four times q.

Keep three labeled quantities in your notes: K = 2 m/day, q = 0.08 m/day and average pore velocity = 0.32 m/day. Their matching units do not make them interchangeable. Each has a different definition and role in the calculation.

Draw a bulk section as a rectangle and label an idealized quarter of it as effective pore area. This is an accounting sketch, not a realistic map of pore geometry. Use it to explain why the same total flow corresponds to a larger average velocity when normalized by the smaller effective area.

Test proportionality with one change at a time

Keep left head at 14 m and double K from 2 to 4 m/day. The driving gradient stays 0.04, q doubles to 0.16 m/day and Q doubles to 3.2 m³/day. The direction remains rightward. Capture both cases and identify which input was held constant.

Return K to 2 and change left head to 6 m. The gradient becomes −0.04, q becomes −0.08 m/day and Q becomes −1.6 m³/day. Negative signs encode right-to-left flow, not a negative amount of water physically present. Their magnitudes match the first case because the head-drop magnitude and conductivity match.

At equal boundary heads, q and Q are zero at every allowed positive K. This is a useful counterexample to the claim that high conductivity alone guarantees fast flow. The model needs a driving difference as well as a transmitting medium.

Transfer and evidence limits

For a paper-only case, take K = 3 m/day, driving gradient −0.02 and bulk cross-section 30 m². Calculate signed q and Q before checking. Then state what would be required to apply the result to a measured aquifer.

Check the Darcy-flow transfer

q = 3 × (−0.02) = −0.06 m/day and Q = 30 × (−0.06) = −1.8 m³/day. Flow is opposite the positive axis. Applying this relation to a real aquifer requires appropriate measurements and evidence that the geometry, conductivity, head gradient and flow assumptions are suitable; the arithmetic alone does not establish them.

Apply

Darcy flux is 0.08 m/day through a 20 m² bulk cross-section. Volumetric flow is:

Public practice checks a specific claim. It does not establish independent mastery.

Show the units in q and Q, explain the bulk-area definition of Darcy flux, and identify assumptions that allow the proportional comparison.

Continue

Completion requires a saved prediction, at least one capture and a reflection. Presence checks do not grade your reasoning.

Skipping retains experiments and awards no mastery.

Save a science backup or import one

Science work is stored locally in this browser, separately from mathematics and AI. It does not sync automatically. Use this science-only backup; this checkout's older all-subject export does not include science.

A legacy file is available only when the complete snapshot fits the 36 MB limit. For larger snapshots, prepare a complete file set below; never discard notebooks to make a smaller file.

Matching imported notebook drafts replace their current drafts. Omitted lessons and known first attempts remain. Export your current work first if you want to retain both drafts.

Complete file sets and course backups

A file set can hold more work than one science file. Keep its manifest and every part together. Each file is limited to 36 MB. This format needs this version of LearnAI or a compatible newer version; older versions can use only the legacy single-file backup above.

The set includes every saved science course and global continuation at this moment. Later edits need a new export. A conflicting tab exports its own visible work, which may differ from saved work in another tab.

0 file(s) selected. File order and filenames do not determine identity. Missing, changed or conflicting parts block the entire restore; no good part is applied by itself.

Science storage: loading. No account or remote computation is required.