Learn

Learning preferences

Make learning more comfortable. Changes apply immediately.

Enlarges page content, including diagrams and their labels. You can also use your browser’s zoom.

Choose the colours that are easiest for you to distinguish. Applies to lesson diagrams and lab plots. Labels, shapes, hatching and line patterns also distinguish meanings. Source photographs and raw image brightness stay unchanged; mask-only views are available for image overlays.

ExampleComparisonSample link

Saved in this browser on this device. Preferences are separate from progress backups.

SCIENCE · INVESTIGATE AND EXPLAIN

Design a dilution with final-volume and uncertainty accounts

Conserve amount while propagating transfer and calibration bounds.

Learning outcome: Compare10/100 and 20/200 nominal volume pairs, then inspect the second-stage bounds. Retain endpoint formulas and distinguish bounded intervals from statistical confidence.

Starting recap

Review amount dimensions, chemical formulas and charge, signed differences, ratio bounds and the distinction between a theoretical constraint and measured conversion.

All lessons are open directly. Your saved experiments remain when you leave and return.

Try

Transferring10 mL of .200 M stock to 100 mL final solution gives .0200 M; adding100 mL solvent is not the same specified final-volume operation.

Open the experiment

Predict

Does a second dilution stage remove uncertainty simply because its nominal factor is convenient?

Experiment

Compare10/100 and 20/200 nominal volume pairs, then inspect the second-stage bounds. Retain endpoint formulas and distinguish bounded intervals from statistical confidence.

Propagate transfer and final-volume bounds through dilution

Worked teaching model · synthetic values · Stock concentration0.200±0.002 mol/L; aliquot bound±0.05 mL and final solution-volume bound±0.20 mL. Independent worst-case intervals, not confidence limits. Optional second stage transfers10.00±0.05 mL to100.00±0.20 mL. No loss/reaction assumed. Final volume is not added solvent volume.

Reset keeps your prediction, captures and practice history.

Calculated evidence under the stated assumptions
QuantityValueUnit
One-stage concentration0.02mol/L
One-stage bounded minimum0.01966168mol/L
One-stage bounded maximum0.02034168mol/L
Second-stage nominal concentration0.002mol/L
Second-stage bounded minimum0.001952432mol/L
Second-stage bounded maximum0.002048436mol/L
Stock amount transferred2mmol

Conserve solute amount while distinguishing final solution volume from added solvent.

Intervals use worst-case monotonic combinations, not a statistical confidence claim. A second transfer can access a smaller concentration but adds measurement bounds. No loss, reaction or volume-temperature mismatch is included; the UI is a virtual design ledger, not evidence of pipetting technique.

Retain the reaction/measurement boundary with every number. This mathematical packet is not a chemical procedure or evidence of actual laboratory technique.

Conserve solute amount while distinguishing final solution volume from added solvent.

Intervals use worst-case monotonic combinations, not a statistical confidence claim. A second transfer can access a smaller concentration but adds measurement bounds. No loss, reaction or volume-temperature mismatch is included; the UI is a virtual design ledger, not evidence of pipetting technique.

Captures preserve recipes and replay their calculated results. They are synthetic model evidence, not physical measurements.

Understand

Begin with amount conservation

Molarity is amount of a specified solute per final solution volume. With no reaction or loss, an aliquot contains n=Cstock Valiquot and dilution gives Cfinal=n/Vfinal. Consistent volume units cancel in the ratio . The final volume is the volume of the entire solution, not the amount of solvent added; real volumes need not add exactly.

Compare equivalent nominal designs

A 10 mL aliquot of .200 mol/L stock contains 2.00 mmol solute. At 100 mL final volume its nominal concentration is .0200 mol/L. A 20 mL aliquot brought to 200 mL has the same nominal concentration but different relative effects from the stated absolute volume bounds. Equal nominal ratios do not imply identical uncertainty budgets.

Propagate the declared bounds

The stock interval is .198–.202 M, aliquot bound±.05 mL and final volume bound±.20 mL. For positive inputs, the smallest concentration uses the smallest stock/aliquot and largest final volume; the largest uses the opposite combination. The10/100 packet therefore uses .198×9.95/100.20 and .202×10.05/99.80 as its endpoints. These are worst-case bounds, not a confidence interval or a standard error.

Audit a serial step

The optional second stage transfers10.00±.05 mL into100.00±.20 mL final volume. Its nominal concentration is one tenth of the first stage, but its interval multiplies the first interval by the corresponding lower and upper volume ratios. It adds an operation and additional bounds rather than making the original stock uncertainty disappear.

Plan beyond the arithmetic

A genuine analytical design would also consider contamination, transfer losses, temperature-dependent calibration and possible correlated volume errors. The workbench does not claim those were checked. It is a virtual comparison with explicit assumptions, not a pipetting protocol or certification. A changed-case report should show the conserved amount, final-volume interpretation, endpoint calculations and at least one omitted error source that an independent measurement could test.

Sources and evidence boundary

Conceptual sources checked 30 October 2026: Molarity and dilution. All prose, cases, code and diagrams are original. The supplied models are not measured structures, a performed laboratory investigation or certification of independent mastery. No chemical handling, heating, pressure vessel or cryogenic experiment is requested. Retain predictions, contrasting evidence and a changed-case explanation.

Apply

The relation C1V1=C2V2 uses V2 as:

Public practice checks a specific claim. It does not establish independent mastery.

Which unmodeled loss, temperature or calibration correlation could change the inference?

Continue

Completion requires a saved prediction, at least one capture and a reflection. Presence checks do not grade your reasoning.

Skipping retains experiments and awards no mastery.

Save a science backup or import one

Science work is stored locally in this browser, separately from mathematics and AI. It does not sync automatically. Use this science-only backup; this checkout's older all-subject export does not include science.

A legacy file is available only when the complete snapshot fits the 36 MB limit. For larger snapshots, prepare a complete file set below; never discard notebooks to make a smaller file.

Matching imported notebook drafts replace their current drafts. Omitted lessons and known first attempts remain. Export your current work first if you want to retain both drafts.

Complete file sets and course backups

A file set can hold more work than one science file. Keep its manifest and every part together. Each file is limited to 36 MB. This format needs this version of LearnAI or a compatible newer version; older versions can use only the legacy single-file backup above.

The set includes every saved science course and global continuation at this moment. Later edits need a new export. A conflicting tab exports its own visible work, which may differ from saved work in another tab.

0 file(s) selected. File order and filenames do not determine identity. Missing, changed or conflicting parts block the entire restore; no good part is applied by itself.

Science storage: loading. No account or remote computation is required.