Learning preferences

Make learning more comfortable. Changes apply immediately.

Enlarges page content, including diagrams and their labels. You can also use your browser’s zoom.

Choose the colours that are easiest for you to distinguish. Applies to lesson diagrams and lab plots. Labels, shapes, hatching and line patterns also distinguish meanings. Source photographs and raw image brightness stay unchanged; mask-only views are available for image overlays.

ExampleComparisonSample link

Saved in this browser on this device. Preferences are separate from progress backups.

SCIENCE · INVESTIGATE AND EXPLAIN

Distinguish titration equivalence, detection and sampling

Track reaction amounts and total volume while comparing true equivalence with a sampled endpoint.

Learning outcome: Calculate a strong-acid titration state and explain how endpoint choice and finite sampling affect an inferred concentration.

Starting recap

Moles equal molarity times volume in liters. The added titrant volume differs from total solution volume. A pH value is not an amount to conserve.

All lessons are open directly. Your saved experiments remain when you leave and return.

Try

If the first sampled point above a detection threshold occurs after equivalence, what happens to the acid concentration inferred from that volume?

Open the experiment

Predict

At 100 mmol/L initial acid, predict the equivalence volume for a 20 mL aliquot and 0.100 mol/L base. Predict pH classification before, at and after that volume.

Experiment

Capture 100 mmol/L acid at 10, 20 and 30 mL added base. Compare 19.75, 20 and 20.25 mL around equivalence. Then change acid concentration to 50 and 150 mmol/L, and explain the changing relative endpoint error.

Track a strong-acid titration with changing total volume

Worked teaching model · synthetic values · Synthetic strong monoprotic acid HX: initial aliquot 20.00 mL, titrant strong hydroxide MOH at 0.100 mol/L, ideal additive volumes and equilibrium at 25 °C. Inert monovalent spectators; water ions retained. A stipulated pH 8.3 detection threshold is illustrative, not a modeled real indicator transition. The 0.25 mL sample grid is not instrument precision; there is no measurement noise, mixing lag or titrant calibration error.

Reset keeps your prediction, captures and practice history.

02468101214010203040pH (logarithmic concentration measure)Added base volume (mL), not total solution volume

The vertical dotted line marks stoichiometric equivalence; the horizontal dashed line marks the illustrative pH 8.3 threshold. The point is your selected state. The curve connects exact calculations every 0.25 mL; its straight segments do not resolve the rapid change between samples. These are synthetic equilibrium states, not instrument readings.

Selected state and distinct endpoint quantities
QuantityValue
Total solution volume40.00 mL
Hydronium1.000000e-7 mol/L
Hydroxide1.000000e-7 mol/L
True equivalence titrant volume20.00 mL
Continuous pH 8.3 threshold20.000796 mL
First grid sample meeting threshold20.25 mL

Spectators: M+ = 5.000000e-2 mol/L; X− = 5.000000e-2 mol/L. H3O+ + M+ and OH− + X− balance electrically. Adding titrant changes both amounts and total volume. Every concentration uses the current total volume; the initial number of acid equivalents stays fixed.

012341234Row number · values in mmol
Calculated values on the same fixed scale
RowQuantityValue (mmol)
1Initial acid equivalents2
2Added base equivalents2
3Excess acid equivalents0
4Excess base equivalents0

pH = 7.000000 at total volume 40.00 mL. Equivalence requires 20.00 mL titrant.

Illustrative pH 8.3 threshold: 20.000796 mL in the continuous calculation. First 0.25 mL grid sample above it: 20.25 mL. Treating that sample as exact equivalence would infer 101.250 mmol/L acid, 1.250% above the assigned concentration. This is sampling/endpoint bias in synthetic data, not a measured uncertainty interval.

Captures preserve recipes and replay their calculated results. They are synthetic model evidence, not physical measurements.

Understand

Start with the number of reacting equivalents

A titration adds a solution of known concentration to a known aliquot volume and uses a detected change to estimate when the reacting amounts match. In this synthetic investigation, the sample is a strong monoprotic acid and the titrant is a strong monobasic hydroxide. The reaction requires one base equivalent per acid equivalent. No practical mixing procedure is supplied by this calculator.

The initial acid aliquot is 20.00 mL. At the starting concentration of 100 mmol/L, or 0.100 mol/L, it contains 0.100 × 0.020 = 0.002 mol = 2 mmol acid equivalents. The titrant concentration is also 0.100 mol/L, so each milliliter supplies 0.100 mmol base. Equivalence therefore requires 20.00 mL added titrant.

The equivalence equation is Cacid Vacid = Cbase Veq for this 1:1 reaction. C means concentration and V means volume in consistent units. Veq is added titrant volume, not the final volume in the vessel. The initial acid concentration is visible as a teaching control; this is not a blind analysis of an unknown sample.

Divide leftovers by the changing total volume

Before equivalence, subtract base equivalents from initial acid equivalents. At 10 mL added base, 1 mmol acid remains in a total volume of 30 mL. Its excess concentration is 1/30 mol/L, approximately 0.033333 mol/L, giving pH about 1.4771. Dividing by the original 20 mL would ignore dilution by titrant.

At 20 mL, the reacting equivalents match. Water’s ions remain, so the ideal strong-acid/strong-base system is neutral at pH 7 at the assigned 25 °C. Spectator ions also remain. This equivalence pH does not apply to every titration: a weak-acid conjugate base can react with water and give a different equivalence pH.

At 30 mL, 1 mmol base is in excess in 50 mL total volume. Hydroxide is approximately 0.020 mol/L, giving pOH about 1.699 and pH about 12.301. The same calculation procedure changes which reagent is in excess, but the final volume must be included on either side.

The model retains both water ions by solving their product relation together with charge balance. That avoids taking a logarithm of zero at equivalence. It assumes ideal additive volumes, inert spectators and constant temperature; actual titration measurements also require calibration, mixing and uncertainty analysis.

Read the curve as states, not as a clock

The horizontal axis is added titrant volume, not elapsed time or total volume. The curve joins calculations every 0.25 mL. Each point represents an equilibrated composition. There is no modeled delay between addition and a stable reading, and the straight segments between points do not reveal the exact shape within each interval.

Compare 19.75, 20.00 and 20.25 mL at the default concentration. The pH changes sharply near equivalence because a small difference in reacting amounts changes which strong reagent is in excess. This is not a discontinuity in the full equilibrium relation. Water’s ions keep the calculation finite, and a finer volume grid would resolve more of the steep region.

Separate three endpoint quantities

The vertical dotted line marks stoichiometric equivalence. The horizontal dashed line marks a stipulated detection threshold at pH 8.3. This is an illustrative rule, not a model of a real indicator’s transition range or its visual uncertainty.

The continuous model crosses pH 8.3 just after equivalence. At the default concentration, the crossing is approximately 20.000796 mL. The first point on the 0.25 mL grid meeting the threshold is 20.25 mL. Those two values answer different questions: where the ideal threshold lies, and where this finite sample schedule first detects it.

Treating 20.25 mL as exact equivalence gives an inferred acid concentration of 0.100 × 20.25/20 = 0.10125 mol/L, or 101.25 mmol/L. That is 1.25% above the assigned concentration. The mismatch arises from the specified endpoint rule and sampling schedule. It is not a statistical confidence interval, a measured instrument error or evidence that every real indicator produces the same bias.

At initial acid concentrations of 50 and 150 mmol/L, equivalence shifts to 10 and 30 mL. On this grid the same additional 0.25 mL gives different relative errors: 2.5% and approximately 0.833%. A fixed absolute volume error is not a fixed relative concentration error.

Decide what better evidence would require

Sampling more closely near the rapid change can reduce overshoot from the chosen grid, but it cannot by itself fix an incorrect titrant concentration, an uncertain aliquot volume, a biased pH sensor or a chemical model that does not apply. A real report should distinguish these sources and justify how equivalence is estimated from its actual measurements.

Transfer: a different 10.00 mL strong monoprotic acid aliquot has a true equivalence volume of 15.00 mL with 0.100 mol/L base. Estimate its concentration, then calculate the relative error if an endpoint of 15.20 mL is used. This aliquot is outside the widget’s fixed 20 mL setting.

Check the titration transfer

The true concentration is 0.100 × 15.00/10.00 = 0.150 mol/L. Using 15.20 mL gives 0.152 mol/L, an overestimate of about 1.333%. The final vessel volume is relevant to pH, but the original aliquot volume belongs in this concentration-inference equation.

OpenStax acid-base titrations provides reference concepts for titration curves and equivalence. The threshold and sampling comparisons here are assigned synthetic investigations.

Apply

A 20 mL strong-acid aliquot requires 20.00 mL of 0.100 mol/L base at true equivalence. Using 20.25 mL instead would infer:

Public practice checks a specific claim. It does not establish independent mastery.

Distinguish added and total volumes, equivalence and detection threshold, continuous crossing and first sampled crossing. Explain why the synthetic endpoint bias is not a measured uncertainty interval.

Continue

Completion requires a saved prediction, at least one capture and a reflection. Presence checks do not grade your reasoning.

Skipping retains experiments and awards no mastery.

Save a science backup or import one

Science work is stored locally in this browser, separately from mathematics and AI. It does not sync automatically. Use this science-only backup; this checkout's older all-subject export does not include science.

A legacy file is available only when the complete snapshot fits the 36 MB limit. For larger snapshots, prepare a complete file set below; never discard notebooks to make a smaller file.

Matching imported notebook drafts replace their current drafts. Omitted lessons and known first attempts remain. Export your current work first if you want to retain both drafts.

Complete file sets and course backups

A file set can hold more work than one science file. Keep its manifest and every part together. Each file is limited to 36 MB. This format needs this version of LearnAI or a compatible newer version; older versions can use only the legacy single-file backup above.

The set includes every saved science course and global continuation at this moment. Later edits need a new export. A conflicting tab exports its own visible work, which may differ from saved work in another tab.

0 file(s) selected. File order and filenames do not determine identity. Missing, changed or conflicting parts block the entire restore; no good part is applied by itself.

Science storage: loading. No account or remote computation is required.