Learn

Learning preferences

Make learning more comfortable. Changes apply immediately.

Enlarges page content, including diagrams and their labels. You can also use your browser’s zoom.

Choose the colours that are easiest for you to distinguish. Applies to lesson diagrams and lab plots. Labels, shapes, hatching and line patterns also distinguish meanings. Source photographs and raw image brightness stay unchanged; mask-only views are available for image overlays.

ExampleComparisonSample link

Saved in this browser on this device. Preferences are separate from progress backups.

SCIENCE · INVESTIGATE AND EXPLAIN

Decide what a coarse density measurement can establish

Propagate two reading bounds and avoid false certainty about material identity.

Learning outcome: Construct conservative density bounds and explain why a coarse displacement can lack a finite upper bound.

Starting recap

A rounded reading has a range of possible underlying values. Subtracting two readings combines their uncertainty; a point estimate is not the whole evidence.

All lessons are open directly. Your saved experiments remain when you leave and return.

Try

Two readings are rounded to 3 mL increments. The displayed displacement is 3 mL for a programmed 5 mL sample. Is the displayed ratio exact?

Open the experiment

Predict

Predict whether a smaller sample or a coarser instrument produces a wider relative uncertainty.

Experiment

Capture increment 1 with sample volume 5, then increment 3 with volume 5. Inspect the missing finite upper bound. Keep increment 3 and increase volume to 25. Compare with the programmed reference.

Propagate reading bounds through density

Worked teaching model · synthetic values · Programmed density 2.7 g/mL; initial volume 50 mL. Each cylinder reading is rounded to the nearest increment, ties upward. Each reading has a half-increment bound; mass readout has a ±0.05 g bound. These worst-case bounds are not confidence intervals and omit bias, bubbles and sample changes.

Reset keeps your prediction, captures and practice history.

Initial reading025507510050 mLFinal reading025507510060 mLDifference: 10 mL · sample mass: 27 g

Both columns use the same 0–100 mL scale. They display rounded instrument readings, not a literal cylinder shape or an animation of immersion. Subtract before calculating density.

051015201234Row number · values in g/mL
Calculated values on the same fixed scale
RowQuantityValue (g/mL)
1Density from displayed readings2.7
2Conservative lower density bound2.45
3Conservative upper density bound3.0056
4Programmed reference density2.7

Displayed displacement 10 mL; point estimate 2.7000 g/mL.

Displacement bound: 9 to 11 mL. Density lower bound 2.4500 g/mL; upper bound 3.0056 g/mL. Repeating these deterministic settings does not supply independent measurements. The bounds conservatively combine endpoint possibilities; they are not a probability distribution.

Captures preserve recipes and replay their calculated results. They are synthetic model evidence, not physical measurements.

Understand

A displayed number has limited resolution

This model uses a programmed sample density of 2.7 g/mL and an initial liquid volume of 50 mL. The reference is a teaching assumption, not a measurement or an identification of a particular material. The sample’s true volume sets its synthetic mass. Cylinder readings are rounded to the selected increment, with exact half-increment ties rounded upward. No random variation is generated.

If the increment is r mL, each displayed reading stands for values within r/2 mL of that reading under the model. The mass display has a separate ±0.05 g bound. These are stated worst-case limits, not standard deviations or confidence intervals. A real instrument may have calibration error, meniscus-reading error and other effects beyond its display increment.

Subtraction uses two readings

Let D be the displayed final reading minus the displayed initial reading. One reading could be high by r/2 while the other is low by r/2. Their difference can therefore be wrong by as much as r. A conservative displacement interval is D − r to D + r, restricted to physically positive volume for a density calculation.

A truly shared additive zero offset can cancel in a difference, but that does not make rounding errors cancel automatically. We use bounds that allow the unfavorable endpoint combination, rather than assuming cancellation or inventing an independence-based probability distribution.

For a true 5 mL sample with increment 1 mL, readings are 50 and 55 mL. D = 5 mL, the mass display is 13.5 g, and the permitted volume is 4–6 mL. The point estimate 13.5/5 = 2.7 g/mL exactly matches the programmed reference, but the permitted range is wider.

Propagate bounds through the ratio

For positive mass and volume, the smallest possible density combines the smallest permitted mass with the largest permitted volume. The largest combines the largest mass with the smallest positive volume. Here the lower bound is 13.45/6 ≈ 2.242 g/mL, and the upper is 13.55/4 = 3.3875 g/mL.

These conservative combinations need not all be simultaneously realizable in a more detailed correlated-instrument model. They are safe endpoint bounds under the stated intervals, not a probability that the density lies near the middle. Do not attach a confidence percentage to them.

Predict before changing the control: retain the 5 mL sample but select increment 3 mL. Which rounded readings will appear, and can the lower displacement limit remain strictly positive?

Check the coarse-reading case

The initial reading rounds from 50 to 51 mL, and the final reading from 55 to 54 mL. Displayed displacement is only 3 mL. Its conservative interval reaches from 0 to 6 mL. The point ratio is 13.5/3 = 4.5 g/mL. Although the true programmed density is still 2.7, the displayed ratio changes because of rounding.

When there is no finite upper bound

If the permitted positive volume can approach zero while mass stays positive, mass divided by volume has no finite upper bound. The app says so and omits an upper-bound point from the chart. It does not replace an unbounded result with zero or clip it silently to the plot ceiling. The lower bound still uses the largest permitted volume.

Larger samples can make a fixed absolute volume error less important relative to displacement, provided the same measurement assumptions remain appropriate. Test volume 25 mL at increment 3 mL. Compare the reference, point estimate and bounds. More repeated clicks on this deterministic model supply no new evidence and cannot estimate empirical variability.

Decide which claims the evidence supports

Consider two hypothetical candidate densities, 2.7 and 3.2 g/mL, under matched conditions. Both lie within the 1 mL-increment interval for the 5 mL sample. That interval alone does not distinguish them. A narrower interval might exclude one candidate under the model, but a surviving candidate is not uniquely identified if other materials or unmodeled errors remain possible.

Save coarse and finer comparisons. Propose a discriminating measurement, explain which error it addresses, and state one error it would leave unresolved. A reviewed investigation should support its identification from several relevant observations, not select the closest tabulated density and ignore uncertainty.

Apply

Each cylinder reading has error bounded by ±1 mL. Without assuming cancellation, the displacement error is bounded by:

Public practice checks a specific claim. It does not establish independent mastery.

Compare a measurement interval with two candidate densities. Explain why an overlapping value remains possible rather than proven, and propose a better measurement.

Continue

Completion requires a saved prediction, at least one capture and a reflection. Presence checks do not grade your reasoning.

Skipping retains experiments and awards no mastery.

Save a science backup or import one

Science work is stored locally in this browser, separately from mathematics and AI. It does not sync automatically. Use this science-only backup; this checkout's older all-subject export does not include science.

A legacy file is available only when the complete snapshot fits the 36 MB limit. For larger snapshots, prepare a complete file set below; never discard notebooks to make a smaller file.

Matching imported notebook drafts replace their current drafts. Omitted lessons and known first attempts remain. Export your current work first if you want to retain both drafts.

Complete file sets and course backups

A file set can hold more work than one science file. Keep its manifest and every part together. Each file is limited to 36 MB. This format needs this version of LearnAI or a compatible newer version; older versions can use only the legacy single-file backup above.

The set includes every saved science course and global continuation at this moment. Later edits need a new export. A conflicting tab exports its own visible work, which may differ from saved work in another tab.

0 file(s) selected. File order and filenames do not determine identity. Missing, changed or conflicting parts block the entire restore; no good part is applied by itself.

Science storage: loading. No account or remote computation is required.