Learn

Learning preferences

Make learning more comfortable. Changes apply immediately.

Enlarges page content, including diagrams and their labels. You can also use your browser’s zoom.

Choose the colours that are easiest for you to distinguish. Applies to lesson diagrams and lab plots. Labels, shapes, hatching and line patterns also distinguish meanings. Source photographs and raw image brightness stay unchanged; mask-only views are available for image overlays.

ExampleComparisonSample link

Saved in this browser on this device. Preferences are separate from progress backups.

SCIENCE · INVESTIGATE AND EXPLAIN

Choose a discriminating reading within a budget

Spend two distinct probes on evidence that separates the remaining explanations.

Learning outcome: Plan sequential readings, retain ambiguity and distinguish a repeated lookup from new independent evidence.

Starting recap

The diagnostic notebook allows two distinct probes per case. Prediction precedes each new reading; repeat views do not add a slot.

All lessons are open directly. Your saved experiments remain when you leave and return.

Try

Terminal voltage of 6 V leaves healthy, open-R1, open-R2 and bypass-R2 hypotheses compatible.

Open the experiment

Predict

Predict which second probe would leave ambiguity after a first terminal-voltage reading, and identify the ambiguous outcomes.

Experiment

Choose an unmeasured case if available and predeclare a probe sequence. Record predictions and up to two distinct readings in the diagnostic notebook. Compare surviving mechanisms with the public paper decision tree; do not reset known exposure.

Diagnose with two distinct readings

Worked teaching model · synthetic values · Original finite ideal-circuit cases. Selecting a probe does not take a reading. A separate notebook preserves predictions and at most two distinct readings per case. Public source and worked answers are available; this is guided practice, not secret assessment. No real circuit is energized.

Reset keeps your prediction, captures and practice history.

Choose evidence before naming a fault

Case A uses one of five supplied ideal hypotheses. All cases and source answers are public. Familiarity, answer reveal and repeated readings are retained; they do not create independent assessment evidence. This notebook is shared across the four diagnosis lessons.

V+−R1 = 100 ΩR2 = 200 ΩJReturn: 0 V referenceNominal source: 6 V
Nominal reference topology, identical for every unrevealed case. Terminal voltage: positive terminal minus return. Junction voltage: J minus return, across R2. Positive loop current flows from the positive terminal through R1 toward R2. Ideal voltage/current meters do not load this model.

Possible explanations: healthy circuit, open R1, open R2, bypassed R2, or weak ideal source. The open cases leave J connected to a source terminal through a resistor. This finite set excludes simultaneous faults, contact resistance and meter loading.

Notebook changes wait while science storage is loading.

Retain your initial plan for case A

Reading allowance: 0/2 distinct probes

Proposed next probe: Source terminal voltage. Choosing it above reveals no value. Repeating a retained probe replays the same reading without spending another slot. Changing cases or resetting controls keeps all case histories.

Case A: ordered, retained predictions and ideal readings
Order / probePrediction before readingValueAnswer already exposed?

Compatible supplied hypotheses: Healthy series pair; Open R1; Open R2; Bypassed R2; Weak ideal source

Compatibility means agreement with the retained readings, not a probability or proof that all real alternatives have been eliminated. Before any reading all five remain. Terminal voltage plus current can leave both open-circuit hypotheses; keep the ambiguity and justify a next test on paper.

This conclusion remains editable; your prior and reading predictions remain unchanged. Generic lesson captures preserve only selectors, not additional readings.

Case A: choose and justify a reading in the notebook.

Generic captures retain selections only. They do not take readings, spend the measurement allowance or establish a diagnosis.

Captures preserve case and proposed-probe selectors only. They reveal no reading and do not replace the shared diagnosis notebook's retained predictions and two-reading limit.

Understand

Decide what a reading could change

A measurement is useful when its possible outcomes change the explanations you can defend. This lab allows two distinct probes per case: terminal voltage, junction voltage and loop current are the available choices. Plan before pressing the reading control. A third distinct probe is outside the case budget, even when it would resolve an inconvenient ambiguity.

The budget counts distinct simulated probe types, not time, money or physical meter connections. Reopening an existing reading neither spends another slot nor generates new evidence. Every new reading needs a prediction first. The dedicated notebook retains case histories across case changes and reloads; a generic lesson capture does not preserve the diagnostic sequence in its place.

Compare two possible first probes

Use the five supplied hypotheses from the circuit explanation. Four predict terminal voltage 6 V; the weak ideal source predicts 3 V. Therefore a first terminal reading of 3 V singles out the weak source within this set. A result of 6 V leaves healthy, open R1, open R2 and bypassed R2 compatible.

A junction reading partitions the same candidates differently: 4 V for healthy, 6 V for open R2, 2 V for the weak source, and 0 V for either open R1 or bypassed R2. It leaves a two-candidate ambiguity for one outcome. This comparison does not require assigning probabilities. The fact that four listed mechanisms share 6 V does not mean a real source has an 80% probability of producing that reading; the list supplies no prevalence distribution.

On paper, draw a decision tree. Label each branch with a possible reading and write the surviving mechanisms at its end. A tree that retains an unresolved set is more honest than one that forces every branch to a diagnosis unsupported by the measurements.

Spend the second probe on the remaining distinction

Suppose you first obtained junction voltage 0 V. The remaining explanations are open R1 and bypassed R2. A terminal-voltage probe would return 6 V for either, so it cannot separate them. A current probe predicts 0 mA for open R1 and 60 mA for the bypass. It addresses the actual unresolved distinction.

Now consider a different history: terminal voltage 6 V, followed by current 0 mA. Both open cases remain compatible. The junction would distinguish them, but the two distinct slots have already been used. Your conclusion should preserve both possibilities and identify the extra measurement you would request if resources were expanded. Do not substitute a remembered case letter for evidence or relabel a revealed answer as a third measurement.

Use the notebook without erasing familiarity

Choose a case with unused readings if one is available. Record a first-probe prediction that includes more than a guessed number: state which outcomes would distinguish which mechanisms. After taking it, update the surviving candidates and predict the second outcome or alternatives before requesting the second probe.

If all cases have been explored, use the retained records to critique your original sequence. Repeated public practice can improve a method without being an unfamiliar assessment. Revealing an answer records exposure; switching away and returning does not undo it. Explain how the evidence sequence supports the conclusion even if you already know the supplied answer.

OpenStax’s instrument discussion explains why voltages and currents involve different connections. This model uses ideal meters: infinite voltmeter resistance and zero ammeter resistance. It does not charge for reconnecting a physical meter, model loading, or supply a practical instrument-operation credential.

Transfer: choose a probe for a new ambiguity

On paper, suppose a changed candidate set contains two ideal-source possibilities, each with total resistance 300 Ω: one source is 6 V and the other 3 V. You may obtain one additional reading, either terminal voltage or current. Predict both possible readings for each probe. Must one choice be uniquely best?

Check the alternative-probe transfer

Terminal voltage would be 6 or 3 V. Current would be 20 or 10 mA because I = V/300 Ω. Either ideal reading distinguishes these two candidates. Without different probe costs, errors or access restrictions, the evidence does not require a uniquely best choice. Those extra conditions would need to be supplied, not invented.

Write a two-sentence method review: what your original next probe could distinguish, and what it could not. Continue to fault localization to connect the readings to node potentials rather than memorized case labels. A good measurement plan uses its resources to resolve a stated question, and can explicitly conclude that the resources were insufficient.

Apply

The two retained readings are terminal voltage 6 V and loop current 0 mA. Within the five supplied hypotheses, which conclusion is supported?

Public practice checks a specific claim. It does not establish independent mastery.

Explain why the number of eliminated hypotheses is not automatically a probability and why an unresolved two-probe result is valid evidence.

Continue

Completion requires a saved prediction, at least one capture and a reflection. This lesson also requires a case with two retained readings and a written diagnosis in the shared circuit notebook. Presence checks do not grade your reasoning.

Skipping retains experiments and awards no mastery.

Save a science backup or import one

Science work is stored locally in this browser, separately from mathematics and AI. It does not sync automatically. Use this science-only backup; this checkout's older all-subject export does not include science.

A legacy file is available only when the complete snapshot fits the 36 MB limit. For larger snapshots, prepare a complete file set below; never discard notebooks to make a smaller file.

Matching imported notebook drafts replace their current drafts. Omitted lessons and known first attempts remain. Export your current work first if you want to retain both drafts.

Complete file sets and course backups

A file set can hold more work than one science file. Keep its manifest and every part together. Each file is limited to 36 MB. This format needs this version of LearnAI or a compatible newer version; older versions can use only the legacy single-file backup above.

The set includes every saved science course and global continuation at this moment. Later edits need a new export. A conflicting tab exports its own visible work, which may differ from saved work in another tab.

0 file(s) selected. File order and filenames do not determine identity. Missing, changed or conflicting parts block the entire restore; no good part is applied by itself.

Science storage: loading. No account or remote computation is required.