Learn

Learning preferences

Make learning more comfortable. Changes apply immediately.

Enlarges page content, including diagrams and their labels. You can also use your browser’s zoom.

Choose the colours that are easiest for you to distinguish. Applies to lesson diagrams and lab plots. Labels, shapes, hatching and line patterns also distinguish meanings. Source photographs and raw image brightness stay unchanged; mask-only views are available for image overlays.

ExampleComparisonSample link

Saved in this browser on this device. Preferences are separate from progress backups.

SCIENCE · INVESTIGATE AND EXPLAIN

Match power, energy and service timing

Compare equal available totals against a time-specific request.

Learning outcome: Convert power times duration and keep request and physical energy accounts separate.

Starting recap

Four hourly bins request 4 kW each; this is a four-hour window, not a full day.

All lessons are open directly. Your saved experiments remain when you leave and return.

Try

A 2 kW device operating for 3 hours uses 6 kWh.

Open the experiment

Predict

Can equal total availability leave different amounts of service unmet?

Experiment

Capture steady and middle generation without storage and close both the physical and availability accounts.

Match generation timing, storage and electrical service

Original four-hour electrical service scenario · separate lifecycle evidence · Original four-hour scenario: four one-hour bins each request 4 kW. All generation packets offer 16 kWh; initial storage is zero. Local supply, surplus charging, deficit discharge and at most 1 kW grid support follow a fixed greedy rule. Curtailed potential is not generated bus input. No forecast, emissions, prices, degradation or reliability certification is calculated.

Reset keeps your prediction, captures and practice history.

Same requested service, different timing and limits

Middle-period availability; Ideal fast storage. Every case requests 4 kW for four one-hour bins: 16 kWh over a four-hour window, not a whole day. Available local generation also totals 16 kWh. Initial storage is zero. Predict whether equal totals are sufficient before comparing the timing and storage controls.

Storage capacity is 4 kWh internal energy. Charge input power is limited to 4 kW; useful discharge output is limited to 4 kW. Charge efficiency is 100% and discharge efficiency is 100%. These are supplied reference profiles, not measured device ratings.

Available generationUsedCurtailed potentialoutside bus inputElectrical busServed electrical demandGrid≤1 kWStorageinternal kWhConversion lossDispatch: local supply → charge surplus / discharge deficit → grid support.Unserved demand is a shortfall against a request, not another energy outflow.

Grid import follows storage discharge and cannot exceed 1 kW. There is no grid charging or grid export. Surplus and deficit cannot coexist in a bin, so charging and discharge never occur together. This stipulated greedy rule is not scheduling optimization. Curtailed potential is unused availability, not generated energy dissipated inside the bus.

Power (kW): available generation bars; dashed requested load at 4 kWEach supplied level is constant within its one-hour bin.02468Bin 1Bin 2Bin 3Bin 4Internal stored energy (kWh): initial 0; end-of-bin bars belowSeparate fixed 0–4 kWh scale; these are boundary snapshots.01234After bin 1After bin 2After bin 3After bin 4A stored amount is not a power or a sum of successive snapshots.

Close two distinct accounts

Physical account (kWh): 12 used local generation + 1 grid + 0 initial store = 13 served + 0 charge loss + 0 discharge loss + 0 final store. Residual: 0.

Availability allocation (kWh): 16 available generation + 1 grid + 0 initial store = 13 served + 4 curtailed potential + 0 conversion losses + 0 final store. Residual: 0. This second account allocates potential generation; it does not imply all availability entered the physical bus.

Served 13 + unserved 3 = 16 kWh requested. Do not add unserved demand to either energy balance, or count battery output a second time as a new primary source.

Each bin lasts 1 h. Energy columns are kWh; the first two numerical columns are kW.
BinDemand kWAvailable kWDemand kWhAvailable kWhDirectCharge inputUsed generationCurtailed potentialStorage outputGridServedUnserved
1404000000113
2484844800040
3484840440040
4404000004040
Internal storage and energy accounts, all in kWh; start + stored charge − internal withdrawal = end.
BinStart storeStored chargeCharge lossInternal withdrawalDischarge lossEnd storePhysical residualAvailability residual
100000000
204000400
340000400
440040000

Reserve and service are different indicators

The illustrative end-reserve target is 1 kWh internal energy. Final store: 0 kWh; reserve shortfall: 1 kWh; target not met. This comparison did not constrain dispatch and does not guarantee future service. It is not another course requirement. Stored internal energy is not identical to deliverable energy for the lossy profile.

The 75% discharge case assigns all modeled loss to discharge for clarity: 4 kWh withdrawn delivers 3 kWh and loses 1 kWh to conversion. It is not a measured battery rating. No self-discharge, aging, thermal constraints, within-bin fluctuations, costs or emissions are calculated.

Check timing, capacity and an unfamiliar duration

Middle-period availability with ideal fast storage ends each bin at [0,4,4,0] kWh. The first bin still has 3 kWh unmet demand: later generation cannot serve an earlier request. With ideal slow storage the stores are [0,1,2,1]; 5 kWh remains unserved across the window despite meeting the final reserve target.

For a separate paper case, an ideal full 4 kWh store limited to 1 kW output can deliver at most 0.5 kWh in half an hour. Multiply power by duration; the numerical equality of kW and kWh in the live one-hour bins is a convenience, not a unit identity.

Served 13 of 16 kWh requested; unserved 3 kWh; final internal store 0 kWh.

Physical account: 12 used local generation + 1 grid = 13 served + 0 losses + 0 final store (kWh). Curtailed available potential 4 kWh is separate. Illustrative reserve shortfall 1 kWh; this does not establish future service.

Captures preserve recipes and replay their calculated results. They are synthetic model evidence, not physical measurements.

Understand

Define the requested quantity before comparing totals

Power describes how quickly energy is transferred. Energy describes the amount transferred over an interval. The model requests 4 kW of electrical service during each of four consecutive one-hour intervals, totaling 16 kWh. This is a four-hour study window, not a complete day or a measured school load.

A defined electrical request is not automatically equal lighting, comfort or other end-use service across different devices. For this investigation, the load at the modeled electrical bus is stipulated. Write that boundary and the time window beside your prediction so a comparison does not quietly change its purpose.

Convert power to energy with units attached

For a constant power P over duration h, energy E = P × h. A 2 kW device operating for 3 hours uses 6 kWh. It does not have a resulting power of 6 kW. Return to circuit power for the connection between electrical quantities and this energy account.

Within each one-hour model bin, numerical kW and kWh values happen to match. This is a duration convention, not an identity between their units. A 4 kW output sustained for half an hour supplies 2 kWh; the same power for two hours supplies 8 kWh.

Make a paper table with one column for interval power and another for interval energy. Do not combine them into a single unlabeled axis. A total-energy comparison can conceal a time mismatch even when every arithmetic conversion is correct.

Compare equal available totals at different times

Select no storage and steady generation. Available powers are [4,4,4,4] kW, matching demand in every bin. All 16 kWh is delivered locally; grid import and unserved demand are zero. Record this baseline before changing the generation timing.

Now choose middle periods, [0,8,8,0] kW, with no storage. It has the same 16 kWh available. In the two middle bins, demand uses 4 kWh each and the other 4 kWh per bin is curtailed potential. In the first and last bins, the grid provides its allowed 1 kWh each but leaves 3 kWh per bin unserved.

The result is 8 kWh used local generation plus 2 imported, giving 10 served and 6 unserved. Capture both settings. Explain why equal available energy did not establish equal supplied service: neither timing nor the limited support source can be discarded from the comparison.

Close two distinct accounts

The middle-period case has an availability allocation of 16 available + 2 grid = 10 served + 8 curtailed potential. Its physical bus account is 8 used local + 2 grid = 10 served. The second account excludes potential that was never generated into this bus.

Unserved demand compares a requested 16 with delivered 10. It is not another 6 kWh of physical output. Similarly, do not add local supply a second time merely because it appears as both an arrow and a contribution to served demand. Keep the request ledger and physical account separate.

The dispatch rule uses local input first and grid support last, with storage between them if selected. It is a stipulated policy, not optimized scheduling. A real system study would need more detailed demand, resource and equipment evidence before translating these four bins into reliability claims.

Transfer: change the duration

A separate fictional interval requests 3 kW for two hours. An available generator can supply 2 kW throughout, with no storage or grid support. Calculate requested, delivered and unserved energy. State why an unserved-energy result alone does not describe every consequence of the interruption.

Check the power-and-service transfer

Requested energy is 6 kWh and delivered energy is 4 kWh, leaving 2 kWh unserved. The demand and supply powers are 3 and 2 kW, not 6 and 4 kW. Consequences also depend on which service is interrupted and when; this calculation supplies no equipment reliability or social-impact assessment.

Apply

A constant 3 kW request lasting two hours is:

Public practice checks a specific claim. It does not establish independent mastery.

Explain why unserved requests and curtailed potential are not extra physical outflows.

Continue

Completion requires a saved prediction, at least one capture and a reflection. Presence checks do not grade your reasoning.

Skipping retains experiments and awards no mastery.

Save a science backup or import one

Science work is stored locally in this browser, separately from mathematics and AI. It does not sync automatically. Use this science-only backup; this checkout's older all-subject export does not include science.

A legacy file is available only when the complete snapshot fits the 36 MB limit. For larger snapshots, prepare a complete file set below; never discard notebooks to make a smaller file.

Matching imported notebook drafts replace their current drafts. Omitted lessons and known first attempts remain. Export your current work first if you want to retain both drafts.

Complete file sets and course backups

A file set can hold more work than one science file. Keep its manifest and every part together. Each file is limited to 36 MB. This format needs this version of LearnAI or a compatible newer version; older versions can use only the legacy single-file backup above.

The set includes every saved science course and global continuation at this moment. Later edits need a new export. A conflicting tab exports its own visible work, which may differ from saved work in another tab.

0 file(s) selected. File order and filenames do not determine identity. Missing, changed or conflicting parts block the entire restore; no good part is applied by itself.

Science storage: loading. No account or remote computation is required.