Understand: Physics Baseline or Statistical Fit?
Optional arithmetic and percentage refresher — return to this activity
A physical model encodes a proposed mechanism; a statistical fit chooses parameters to match data. Excess temperature is the amount above room temperature. Retaining 0.8 of that excess each minute makes a curve. A line changes by the same degrees per minute. Neither method earns trust just from its name.
Cooling comparison: synthetic measurement pack v1
All people, records and numbers in this pack are authored teaching examples. They are not records or performance claims about real organizations.
- S1 · At minutes 0–6, authored temperatures are 80, 68, 59, 51, 45, 40, 36 °C. They simulate an experiment, not physical measurements. Each value has a stated ±1 °C reading interval for the exercise.
- S2 · Initial temperature is 80 °C; recorded room temperature is 20 °C. A simplified baseline retains 0.8 of excess temperature each minute: T(t)=A+(80−A)×0.8^t. A is assumed room temperature in °C; t is whole minutes; T is predicted °C. The exponent 0.8^t means multiplying by 0.8 once for each minute; at t=0 the factor is 1. The fraction 0.8 is supplied, not fitted on monitoring data.
- S3 · A straight line is fitted by least squares to minutes 0–3 only. Least squares minimizes summed squared training residuals. Its slope is −9.6 °C/min and intercept 78.9 °C.
- S4 · Minutes 4–6 are exposed monitoring cases outside the fitting interval, not an untouched test. Residual = observation − prediction; MAE = mean absolute residual. The reading interval is not automatically a confidence interval.
- S5 · The physical form assumes a stable environment and cooling fraction. Changed cup, airflow or room temperature can invalidate it. A line extrapolated far enough can predict below room temperature.
- S6 · The downloadable standard-library Python starter records input identity, configuration, row roles, runtime, coefficients and errors. No random step is used, so no seed is required. Exact bytes across every platform are not promised.
Worked example
At A=20 the physical model starts at 80 and predicts 68 at minute 1. The training means are t̄=1.5 minutes and T̄=64.5 °C. A bar means an average; Σ means add the expression over the four training rows. Slope is Σ(t−t̄)(T−T̄)/Σ(t−t̄)²=−48/5=−9.6 °C/min. Intercept is 64.5−(−9.6×1.5)=78.9 °C. Each sum uses minutes 0–3 only.
Your next action
Compare both methods at A=20. Reproduce a fitted coefficient or prediction, report training and monitoring MAE separately, and explain the physical and statistical assumptions.
These are authored public practice cases. Retain your reasoning and uncertainty. A completed page does not establish independent proficiency.
Authored explanation · fixed examples, not a live experiment.
Model decaying excess above room temperature
→Fit a line from four training points
→Compare separate training and monitoring errors
What does each model fit, and what does it assume?